Specifications – TL Audio A4 User Manual

Page 13

Advertising
background image

13

SPECIFICATIONS



Inputs:

Balanced, via 3 pin TRS jack, or 25pin D-Sub per 8 channels.

Input impedance: greater than 10Kohm.

Nominal Level +4dBu or -10dBu, switched in banks of 8

channels.


Pan Controls:

-3dB at centre.

Attention when panned fully left or right: 60dB.


Tube Stage:

Switchable tube stage on stereo mix, pre insertion point.

“Warmth” control varies THD from typically 0.3% to 10%,

predominately second harmonic.


Insertion Point:

Balanced, via separate 3 pin TRS jack send and return.

Nominal level +4dBu or -10dBu.


Drive LEDs:

Variable intensity, from 0dBu to +12dBu, indicating increasing
Tube drive.


Tube Peak LEDs:

Illuminates when tube stage is overdriven into clipping.


Master Level:

Maximum Gain +6dB.


Output Peak LEDs: Located above VU meters, illuminate at +22dBu on output

at +4dBu nominal level, or +8dBu at -10dBu nominal level.

Outputs:

Balanced, via 3 pin XLR connectors.
Nominal level +4dBu or -10dBu.

Maximum Level:

+26dBu, Input to Output @ 0dB gain and +4dBu nominal

level.


Frequency Response: +0, -1dB, 10Hz to 25KHz.

Distortion:

0.012% at 1KHz.
0.05%, 20Hz to 20KHz.
(At +4dBu input and output and 0dB gain, tube stage out).


Hum and Noise:

-83dBu unweighted, at 0dB gain and +4dBu nominal level.


VU Meters:

Illuminated moving coil, 0VU = +4dBu (or -10dBu).

“+10dB” switch shifts 0VU to +14dBu (or 0dBu).


Advertising