A correctly designed balanced interface should have both phase and non-phase signals
of equal magnitude (and source impedance), but should allow either of the phase and
non-phase signals to be connected to an arbitrary electrical point (e.g. ground) without
changing the differential level. Therefore, if, for instance, the non-phase signal is
shorted to ground by an unbalanced input on a piece of equipment, then the phase
signal should double in magnitude to compensate. Such an arrangement is referred to
as “floating” or “ground-free”. Balanced signals require 3 pin connectors, such as
XLR’s or TRS jack plugs, carrying the phase and non-phase signals, plus a screening
ground connection.

Naturally, the Ebony Series features balanced, ground-free signals for all line inputs
and outputs, as well as insertion points where present. The range is also compatible
with unbalanced equipment, as described above.