Warning, Manual mute terminal connection, Output connections – Toa BG-235 User Manual

Page 9

Advertising
background image

9

6.4. Manual Mute Terminal Connection

Closing the manual mute (+) and (–) terminals
causes the Mute Receive inputs to be muted
(the inputs set to be muted).

MANUAL

MUTE

MIC / LINE 1

H

C

+

-

E

Short-circuit current:
Open voltage:

1 mA or less
35 V or less

6.2.2. LINE 2, LINE 3 input connections

LINE 2

H

E

E

H

Input source

Input source

Input source

H

E

H

E

Upper and lower RCA inputs are internally, passively mixed.

6.3. Output Connections

6.3.1. Speaker connections

Each amplifier has 3 speaker outputs: 4 Ω, 25 V, and 70 V. Use only one of these outputs for connection.
Class 2 wiring may be used.

Note: Impedances in the figures below represent total speaker load impedance.

70 V LINE
Total impedance
245 Ω (BG-220)
140 Ω (BG-235)

25 V LINE
Total impedance
31 Ω (BG-220)
18 Ω (BG-235)

Speaker output terminal

COM 4 Ω

Speaker output terminal

COM

25 V

Speaker output terminal

COM

70 V

4 – 16 Ω

70 V Line

25 V Line

The terminals marked with the symbol are hazardous live.
The external wiring to these terminals requires installation by an
instructed person.

WARNING

6.3.2. MOH output connection

The MOH output is 0 dB*, 600 Ω, and balanced (transformer-isolated).

* 0 dB = 1 V

MOH OUT (ZONE2)

600Ω

H

C

E

MOH OUT (ZONE2)

600Ω

H

C

E

Note

C
E

H

E

H

When connecting equipment with
unbalanced input, short-circuit the "C"
and "E" lines as shown at right.

6.3.3. Line output connection

The Line output is 0 dB*, 600 Ω, and unbalanced.

* 0 dB = 1 V

LINE OUT

600Ω

H

E

E

H

Advertising