9.4. Making Fine Acoustic Adjustment

When finer acoustic adjustment is required, different ARC filters can be set for individual output channels.

[Setting example in a gymnasium where the unit's output channels are assigned as follows]

Set different ARC filters to the MONO OUT 1 channel and STEREO OUT channel.

MONO OUT 1 channel

STEREO OUT channel

1

-3

1

-2

Press in (ON).

1-1. Turn the MONO 1's input level control knob to the 12 o'clock

position.

1-2. Press in only the MONO 1’s Assignment switch "1" to turn it

ON.

1: ON

2: OFF

ST: OFF

1-3. Turn the MONO 1's output level control knob to the 12

o'clock position.

1-4. Adjust the volume level of the output amplifier connected to

the MONO OUT 1.

1-5. Conduct ARC measurement. (See Step 7 on p. 17.)

The ARC filter is assigned to the MONO OUT 1 channel.

Cable wiring example

• MONO OUT 1 channel: Ceiling speakers

• MONO OUT 2 channel: No connection

• STEREO OUT channel: Stereo speakers installed at

both sides of the stage

Step 1. Set the ARC filter only to the MONO OUT 1 channel (ceiling speakers).