25

[Rear]

17. Stereo output terminals

0 dB*, 1 kΩ, electronically balanced type.

Use the supplied removable terminal plug for

connection.

18. Auto mute switch

Used to turn on and off the Automatic Mute

function (AUTO MUTE).

19. Input sensitivity selector switches

Used to select the input sensitivity and phantom

power ON/OFF.

Note

Set to "PHANTOM" only when connecting a

microphone which requires phantom power (+24

V, 10 mA) to the corresponding input terminal.

Connecting an equipment other than this type of

microphone to the input terminal set to PHANTOM

may cause the unit to malfunction or may generate

hum noise.

20. AC inlet

Connect this inlet to the AC wall outlet using the

supplied power cord.

21. Functional ground terminal

Hum noise may be generated when external

equipment is connected to the unit. Connecting

this terminal to the functional ground terminal

of the external equipment may reduce the hum

noise.

Note: This ground is not for protective ground.

22. Monaural output terminals

0 dB*, 1 kΩ, electronically balanced type.

Use the supplied removable terminal plug for

connection.

23. Recording output terminal

–10 dB*, 1 kΩ, unbalanced type.

Use an RCA plug for connection.

24. Stereo input terminals

–10 dB*, 10 kΩ, unbalanced type.

Use an RCA plug for connection.

STEREO IN1 is internally connected in parallel to

the front-mounted stereo input jack (11).

25. Monaural input terminals

Input level can be selected by the input level

selector switch (19) position as follows.

LINE:

–10 dB*/2.4 kΩ

MIC:

–46 dB*/2.4 kΩ

PHANTOM: –46 dB*/2.4 kΩ

Removable terminal blocks and phone jacks

are provided. Both terminals are electronically

balanced type and internally connected in parallel.

* 0 dB = 1 V