Parameter settings – Triner Scale iForks Pt2 User Manual

Page 21

Advertising
background image

OWNERS MANUAL

i

Forks

41

2. Parameter settings

Par.

Function

Default
settings
EU US

Settings

01

Calibration and start-up units (and print units)

kg

lb

kg;lb

02

Smallest graduation step for multirange

1

2

0.1/0.2/0.5/1/2/5/10/20/50

03

Biggest graduation step for multirange

2

5

0.1/0.2/0.5/1/2/5/10/20/50

04

Number of divisions for every range

1000

1000

0000 - 9999 divisions

05

Weighing capacity system (full scale)

2500

5000

0-99999

06

Motion tolerance for stable

2

2

off/0.5/1/2/4/8/16/32 grad./sec

07

Filter size

8

8

off; 1-12 (1 light filtering, 12 high filtering)

08

Auto zero range (zero track)

0.5

0.5

off/0.5/1/3 grad./sec

09

Zero range positive (+)

10

10

0-100 % of span

10

Zero range negative (-)

10

10

0-100 % of span

11

Test function (display service mode)

basic

basic

basic/count/res10

12

Power on

– automatic zero

no

no

Yes/no

13

Approved / non-approved version

no

no

No/ntep/oiml

14

Sampling quantity

10

10

1/2/5/10/20/50/95

15

Units switch mode active

yes

yes

no/yes

16

Setpoint function

0

0

0 (not used); 1 (gross overload); 2 (net overload); 3
(fill manual tare); 4 (fill auto tare); 5 (gross overload
not authorize to change gross setting); 6 (net overload
not authorize to change net setting); 7(gross overload
delayed); 8 (net overload delayed); 9 (gross overload
delay not authorize to change gross setting); 10 (net
overload delay not authorize to change net setting)

17

Number of wires per loadcell (sence active)

4

4

4/6

18

Gravity value working area

9.812

9.797

9.750-9.850

19

Print format date/time

EU

US

EU (dd/mm/yy);US (mm/dd/yy)

20

Baudrate com1

9600

9600

600/1200/2400/4800/9600/19200

21

Setting com1

8_n_1

8_n_1

8_n_1; 8_n_2; 7_n_1; 7_n_2

24

End character com1

cr

cr

cr;lf;crlf

25

Protocol com1

5

5

0(PC bi-directional NU); 1(PC Excel format on print
command); 2 (remote display); 3 (printer protocol with
power control); 4 (printer protocol without power
control); 5 (Bluetooth master)

26

Number of linefeeds com1

4

4

0-9

27

Handshake com1

soft

soft

soft (Xon/Xoff)/hard (CTS)

28

Printout format for com1 and com2

stnd

stnd

stnd;total;confi

29

Header lines added

0

0

0 - 3

30

Baudrate com2

9600

9600

600/1200/2400/4800/9600/19200

31

Setting com2

8_n_1

8_n_1

8_n_1; 8_n_2; 7_n_1; 7_n_2

34

End character com2

cr

cr

cr/lf/crlf

35

Protocol com2

0

0

0(PC bi-directional NU); 1(PC Excel format on print
command); 2 (remote display); 3 (printer protocol with
power control); 4 (printer protocol without power
control); 5 (Bluetooth master)

36

Number of linefeeds com2

4

4

0-9

37

Handshake com2

soft

soft

soft (Xon/Xoff)/hard (CTS)

40

Level sensor

no

no

no/ls nc/ls no/cs fa/cs ra

41

Delay trigger time level sensor

3

3

0 -1 0 sec

43

Compensation factor correction factor

1

1

0.1-10.0

44

Compensation factor X-direction

1

1

0.1-10.0

45

Compensation factor Y-direction

1

1

0.1-10.0

60

Battery used

6

6

6V /12V

61

Low Bat switch-off time

2

2

0 = never off; 1-99 min

62

Auto shut-off time indicator

2

2

0 = never off; 1-99 min

63

Auto shut-off time forks

3

3

0 = never off; 1 = 30min; 2 = 1h; 3 = 2h

64

Sleep time indicator if used

0

0

0 = not used; 1 to 99 min

65

Auto shut-off time backlight

20

20

off/20/40/80/160/320 sec

66

Backlight brightness

100

100

100%/ 75%/ 50%/ 25%/ 0% (off)

67

Low bat switch off time forks

10

10

0 = never off; 1-99 min

68

Buzzer function active

off

off

off/ on (direct); on (2 sec. delay)

80

Digital corner calibration active

0

0

0 (enabled); 1 (disabled)

81

Compensation factor digital corner A

1.000

1.000

Do not change value after digital corner calibration

82

Compensation factor digital corner B

1.000

1.000

Do not change value after digital corner calibration

83

Compensation factor digital corner C

1.000

1.000

Do not change value after digital corner calibration

84

Compensation factor digital corner D

1.000

1.000

Do not change value after digital corner calibration

85

Matching Bluetooth forks

Only enter this parameter to establish a complete new

Advertising