Optional Level Indicator Modes

The Peak-Hold level indicators can operate in two modes. As supplied, only the

OL and

PK indicators will hold (after they are activated) until RESET is depressed. An optional

mode is available which causes the

-3 and -6 indicators to also hold until RESET is

depressed. This mode can be helpful in live sound and recording applications where the

Precision 8 is remotely located from the device(s) to which it is connected. Jumpers
inside the unit select this optional mode. If you wish to configure the unit for this mode,
proceed as follows:


WARNING - ELECTRIC SHOCK HAZARD. Dangerous voltage exists inside
the enclosure of this product. This operation should only be performed by
qualified personnel. NEVER open the product enclosure while the AC power

cord is attached.

Disconnect AC power cord.

Remove the twelve screws securing the top cover to the enclosure. Remove the
cover.

Locate the eight upright printed circuit boards along the front panel.

Select level indicator mode by setting jumpers (J2) as shown below.


J2

J2





Normal Mode

Optional Mode

(

OL, PK remain on)

(

OL, PK, -3, -6 remain on)

Replace cover and secure with twelve screws. Make sure no tools, loose hardware,
debris, etc. remain in the unit prior to attaching the cover.