Liquid propane gas connection-built in appliction – Twin Eagles TPSS-13F User Manual

Page 8

Advertising
background image

LIQUID PROPANE GAS CONNECTION-BUILT IN APPLICTION


Notice

All gas installations, conversions, and/or adjustments must be performed by an authorized
service agent.


Notice

If your Infrared Sear Station is for built-in application, a factory supplied L.P regulator is set for
11” WC and is for use with L.P. gas only. The factory-supplied regulator and hose must be
used with a 20 lb. L.P. cylinder. For plumb-in installation (system L.P. installation), the regulator
must be changed and a main gas shutoff valve must be installed. Contact your Twin Eagles
dealer for a system L.P. regulator.

Warning

The gas supply hose should be inspected prior to each use. Do not use a gas hose that has
abrasions, cuts, or excessive wear.

The gas supply must be turned off at the LP Gas supply cylinder and the LP Gas supply cylinder
must be disconnected from the regulator when this outdoor cooking gas appliance is not in use.

When your Infrared Sear Station is stored indoors, remove and store the LP Gas cylinder
outdoors in a protected, cool, and dry location out of reach of children. The cylinder should not
be stored in a building, garage, or any other enclosed area.

Caution

Store the cylinder in an upright position so that the cylinder valve is at the top. This will ensure
proper vapor withdrawal.

The cylinder used must include a collar to protect the cylinder valve.

Store any spare or extra gas cylinder(s) at least 15 feet from the Infrared Sear Station, other
open flame, heat-producing appliance(s) or heat source in a cool, well-ventilated outdoor
location.

NOTE: An enclosure for a propane gas cylinder shall be vented by openings on the level of the
cylinder valve and at floor level. The effectiveness of the opening(s) for purposes of ventilation
shall be determined with the propane gas supply cylinder in place. This shall be accomplished
by one of the following:

a. One side of the enclosure shall be completely open; or,
b. For an enclosure having four sides, a top and a bottom:

1. At least two ventilation openings at cylinder valve level shall be provided in

the sidewall, equally sized, spaced at 180 degrees (3.14 rad), and
unobstructed. Each opening shall have a total free area of not less than ½
square inch per pound (7.1cm²/kg) of stored fuel capacity and not less than a
total free area of 10 square inches (64 cm²).

2. Ventilation opening(s) shall be provided at floor level and shall have total free

area of not less than ½ square inch per pound (7.1 cm²/kg) of stored fuel

7