13 

 

 After  approximately  25  seconds,  the  format  buttons will  flash  and then  a  single  format  LED  will  light.    The 

display should show the fader level and the selected format. 

 Press  each  of  the  format  buttons,  verifying  that  the  corresponding  LED  lights  and  that  the  display  changes 

accordingly.  Note that the format button LEDs for digital formats will flash when no digital input is provided. 

 Press the mute button verifying that its LED toggles each time the button is pressed. 
 Rotate the fader in each direction verifying that the fader numbers on the display change. 

 

6.2   

System Hardware Mounting, Grounding and Ventilation 

The  JSD‐100  is  designed  to  mount  in  a  standard  19  inch  (482.6mm)  rack  and  is  two  rack  units  high  (3.5  inches, 
137.8mm).  The JSD‐100 should be mounted at “eye level” in the equipment rack for optimum display contrast and 
visibility.  We recommend vented panels (USL part number VP‐1) above and below the JSD‐100 whenever space 
permits.  Mounting the unit immediately above a major heat‐producing component, such as a power amplifier, is 
not  recommended.    Equipment  mounted  immediately  above  the  JSD‐100  should  not  be  more  than  9  inches 
(225mm) deep to insure adequate airflow through the rear ventilation slots on the JSD‐100.  The JSD‐100 includes 
a three‐prong grounding plug and a three‐wire power cord to accommodate a safe ground path from the chassis to 
the electrical system ground.  Defeating this ground by removing the ground prong is not recommended. 

 

6.3   

Eight Channel Analog Output Rear Panel Connections 

A set of clip‐on ferrite “beads” is supplied with the JSD‐100.  To insure the JSD‐100 continues to meet FCC and CE 
radio  emissions  requirements,  one  of  these  beads  should  be  clipped  around  each  cable  connected  to  the  rear 
panel of the JSD‐100 except for the TOSLINK, AC Power, and Bypass Power connection. 

 

1. Bypass Power Supply – 12VDC at 1.25A. 
2. Power entry Module – Accepts IEC‐type line cord from 100‐240VAC power source.  Also contains a 500mA Slo‐

Blo 5x20mm fuse. 

3. Eight Channel Analog Output Module – Other modules include 16 channel analog and 32 channel AES. 

a. 8 Channel Analog Module provides six fixed outputs (L, C, R, LFE, Ls, Rs) and two that can be set up as 

either  Lc/Rc  or  Lrs/Rrs.    Balanced  line  Phoenix  and  DB25M  connectors  are  provided.    The  Phoenix 
connector  normally  drives  auditorium  amplifiers  and  the  DB25M  connector  normally  drives  a  booth 
monitor. 

b. USL  Link  ‐  An  RJ25  connector  that  provides  an  RS‐485  interface  for  remote  volume  control  and  other 

functions. 

4. Ethernet – Network communications with GUI, web browsers, automation, etc. 
5. RS‐232 on a DE9F connector for communications with GUI or automation. 
6. Automation DB25F Connector – A bidirectional port for receiving and sending automation pulses between the 

JSD‐100 and other system components.  12 Control lines, 11 Status lines and +5V are provided.  Standard pulse 
to ground system.   

7. SD Card – Stores a backup copy of unit configuration.  Can also be used to transfer settings to another unit. 
8. AES connector (DB25F) – Channels 1‐8 are standard.   Channels 9‐16 require the optional DI‐80 module. 
9. AES connectors (Dual RJ45s) – parallel connections to the DB25F above. 