The Configuration Page shows the same auditorium data and network data as the status page.  When first 
accessing the configuration page, you will be asked for a username and password.  The username is admin.  The 
default password is ultra.  To change the password, enter it twice at the bottom of the configuration page, then 
press the “Save New Password” button.  The Configuration Page has a link to the Update Firmware page.  

 

The Update Firmware Page allows the firmware in the two DSPs and the main processor (PIC) to be updated.  

 

Firmware is usually delivered in a Software Package that includes new versions of the code for each DSP and the 
main processor (PIC).  We suggest making the updates in this order: DSP2, DSP1, PIC.  Look at the versions of each 
piece of code in the software package.  If one of the versions is already installed in the JSD‐100, that portion of the 
JSD‐100 does not need to be updated.  The currently installed firmware version is shown on the Update button for 
each processor. 

 

Select the device to be updated:  DSP2, DSP1, or the main processor (PIC).  Press the “Browse” button to select the 
file to be downloaded to the JSD‐100.  Press the “Update” button.  During the update, the front panel LEDs on the 
JSD‐100 will flash.  After an update of the main processor, the JSD‐100 will reset to start executing the new code.  
The browser will disconnect at that time. 
 
9. SNMP Monitoring 

 

The JSD‐100 includes an SNMP agent that can be used with an SNMP network manager or MIB browser to monitor 
the status of the JSD‐100.  The MIB describing the JSD‐100 is located at http://JSD‐100/JSD100.MIB .  Substitute 
the  IP  address  of  the  JSD‐100  for  JSD‐100  in  the  preceding  URL.    At  this  time,  the  status  of  the  JSD‐100  can  be 
polled using SNMP.  View the MIB for the details of what is currently supported. Control through SNMP and SNMP 
traps are not currently supported. Below is a portion of an SNMP walk of a system. 
 

C:>snmpwalk ‐v 1 ‐c public 192.168.1.159 iso 
SNMPv2‐MIB::sysDescr.0 = STRING: digital cinema sound processor 
SNMPv2‐MIB::sysObjectID.0 = OID: SNMPv2‐SMI::enterprises.38012 
DISMAN‐EVENT‐MIB::sysUpTimeInstance = Timeticks: (267754) 0:44:37.54 
SNMPv2‐MIB::sysContact.0 = STRING: [email protected] 
SNMPv2‐MIB::sysName.0 = STRING: USL JSD‐100MA, HW ver E, Main PIC ver 110630, DSP 1 ver 1110525, 
DSP 2 ver 2110525, Rear Panel ver 110512 
SNMPv2‐MIB::sysLocation.0 = STRING: San Luis Obispo, CA USA 
SNMPv2‐MIB::sysServices.0 = INTEGER: 7 
SNMPv2‐SMI::enterprises.38012.1.1.0 = STRING: "USL JSD‐100MA" 
SNMPv2‐SMI::enterprises.38012.1.2.0 = STRING: "12345" 
SNMPv2‐SMI::enterprises.38012.1.3.0 = STRING: "E" 
SNMPv2‐SMI::enterprises.38012.1.4.0 = STRING: "110630" 
SNMPv2‐SMI::enterprises.38012.1.5.0 = STRING: "1110525" 
SNMPv2‐SMI::enterprises.38012.1.6.0 = STRING: "2110525" 
SNMPv2‐SMI::enterprises.38012.1.7.0 = STRING: "Analog 16" 
SNMPv2‐SMI::enterprises.38012.1.8.0 = STRING: "110512" 
SNMPv2‐SMI::enterprises.38012.2.1.0 = STRING: "JSD‐100        " 
SNMPv2‐SMI::enterprises.38012.2.2.0 = IpAddress: 192.168.1.159 
SNMPv2‐SMI::enterprises.38012.2.3.0 = IpAddress: 255.255.255.0 
SNMPv2‐SMI::enterprises.38012.2.4.0 = IpAddress: 192.168.1.1 
SNMPv2‐SMI::enterprises.38012.2.5.0 = STRING: "69.25.96.13" 
SNMPv2‐SMI::enterprises.38012.3.1.0 = STRING: "USL San Luis Obispo" 
SNMPv2‐SMI::enterprises.38012.3.2.0 = INTEGER: 0 
SNMPv2‐SMI::enterprises.38012.3.3.0 = INTEGER: 1 
SNMPv2‐SMI::enterprises.38012.4.1.0 = INTEGER: 8 