Lighting instructions – CFM Corporation 7000 User Manual

Page 25

Advertising
background image

IGNITER LIGHTING SYSTEM

The Igniter System consists of an igniter unit,

a gas-collector box, two ceramic electrodes,
and lead wires. Gas is collected in the metal
collector box located at the burner. When the
igniter knob is turned, an electric spark is creat-
ed at the ceramic electrodes. The gas is then
ignited by the spark.

To test: Watch the electrode tip(s) inside the

gas collector while activating the igniter. To
avoid a possible shock, do not touch the burner
or metal parts on igniter system while perform-
ing igniter test. A visible spark should jump
from the electrode. The spark gap is set when
the electrode is installed.

If there isn’t a spark, check the lead wires and

connections. The igniter wires should be kept
away from the grill bottom. Also check that the
ceramic electrodes in the collector box are not
broken.

Sometimes dirt and rust at and around the

electrode(s) can prevent an igniter spark. Clean
them with a degreaser or warm soapy water,
and dry. Remove rust from electrode tip(s) and
metal surfaces by lightly sanding with an emery
cloth or fine-grain sandpaper.

LIGHTING INSTRUCTIONS

(Read all the steps before beginning.)

STEP 1. Check the burner venturi tubes for

blockage from an insect nest (see, “CLEANING
THE BURNER VENTURI T U B E S ” ) .

STEP 2. Ensure that both of the burner-control

knobs are in the OFF position.

STEP 3.

OPEN GRILL LID

WARNING: Attempting to light the grill with the

lid down could cause an explosion.

STEP 4. Go behind the grill and turn on the

fuel supply valve. One counter-clockwise turn is
generally enough to open the valve.

CAUTION: Do not stand with head or arms over

the grill.

STEP 5. To light using the igniter:
Push in and turn the right burner-control

knob counter-clockwise to the high setting.

STEP 6.
Immediately turn the igniter control knob

CLOCKWISE until you hear 4 or 5 clicks.

The burner should light.
Note: Turning the knob in the wrong direction

may loosen it. If this happens, simply press the
knob on firmly and turn it CLOCKWISE.

STEP 7.
If the burner fails to light properly, turn the burn-

er-control knob off. Also turn off the L.P. cylinder
knob. Wait five minutes before attempting to light
the burner again. This will allow time for released
gas to disperse.

HINT: If the burner does not light after trying

again, turn off burner-control knob, the L.P. cylin-
der knob and try match lighting the grill once the
gas has cleared.

Lighting Instructions

25

Operating the Control Knobs

Gas control knobs PRESS IN and rotate counter-
clockwise.
ROTATE THE IGNITER KNOB CLOCKWISE.

Advertising