Flanged foot detail, Specifications, Dimensions – Cleveland Range Open Base & Modular Gas Skillet SGM-30-TR User Manual

Page 2

Advertising
background image

SECT.

XII

PAGE

8

0707

Litho in U.S.A.

(NOT TO SCALE)

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., NSF, CGA, CSA, ETL and others.

32"

813mm

30"

762mm

SUGGESTED

FLOOR

DRAIN

GRATE

12"

305mm

23 1/2"
597mm

(PAN

SURFACE)

35"

889mm

40"

1016mm

37"

940mm

42"

1067mm

28"

711mm

26"

660mm

4 1/2"

114mm

33 1/2"
851mm

13"

330mm

26"

660mm

15 1/4"
387mm

3 1/2"
89mm

72"

1829mm

(COVER

FULLY

OPEN)

A

B

(PAN SURFACE)

LIP (CENTERED ON SKILLET)

DRAIN
PAN

TD 2

TD 2 &
DRAIN PAN

DOUBLE
PANTRY
FAUCET

TD 2 OUTLET

PIPE DRAIN RECOMMENDED

MINIMUM VALVE SIZE PLUS 1" (26mm)

RECOMMENDED

FLOOR SLOPE

1" (26mm) IN

4’ (1220mm)

P

A

N

I

N

F

U

L

L

T

IL

T

P

O

S

IT

IO

N

1 1/4 NPT (DRAIN PIPE)

D

E

SUGGESTED

FLOOR DRAIN

GRATE FOR

TD 2

15"

381mm

28"

711mm

7/16" , 3 HOLES
ON 2 3/4" (70mm) B.C.D.

FLANGED

FOOT DETAIL

(REAR LEGS ONLY

)

120

°

120

°

3 1/2" (89mm)

1" (26mm)

(MAXIMUM

ADJUSTMENT

2" (51mm)

4"

102mm

16 1/2"
419mm

6"

153mm

23"

584mm

6 1/4"

159mm

VOLTS: 120

PHASE: 1

AMPS:

1.8

FREQ:

60 HZ

220/240

1

.83

50 HZ

ELECTRICAL
SUPPLY
(6’ CORD & PLUG)

TYPE: NAT or LP

WATER COLUMN: 4.5 (NAT), 10.5 (LP)

BTU PER CU. FT.: 1000 (NAT), 2500 (LP)

SUPPLY PRESSURE:

5" W.C. MIN (NAT), 11" W.C. MIN (LP)

BTU RATINGS:

SGL-30-TR: 91,000 per hour

SGL-40-TR: 130,000 per hour

SGL-30-TR

440 LBS.

200 KG.

SGL-40-TR

520 LBS.

237 KG

APPROX.
SHIPPING
WEIGHTS

GAS SUPPLY
(PIPING 3/4" NPT)

CLEARANCE

SPECIFICATIONS

MODEL

SGL-30-TR

SGL-40-TR

A

36"

(915mm)

48"

(1220mm)

DIMENSIONS

B

32"

(812mm)

44"

(1118mm)

C

9"

(229mm)

12 1/8"

(308mm)

D

5"

(127mm)

8"

(203mm)

E

20"

(508mm)

22"

(559mm)

NOTE

: NON STANDARD ITEMS ARE SHOWN IN GRAY

MIN. TO COMBUSTABLE

SURFACES:

SIDES: 0, REAR: 6" (153mm)

MIN. TO NON COMBUSTABLE

SURFACES: SIDES & REAR: 0

NOTE: 4 1/2" (115mm) required

on right hand side for faucet

EXTERIOR HINGES

REQUIRED FOR
OPTIONAL TD 2

In 4 oz. servings. Other sizes may be calculated.

30 gallons / 115 Liters ............. 960

40 gallons / 150 Liters ............1280

CAPACITIES

EXTERIOR HINGES
(REQUIRED FOR
OPTIONAL TD 2)

Advertising
This manual is related to the following products: