Safety sensors wire open
(broken or disconnected).

OR

Safety sensors wire
shorted or biack/white

wire reversed.

Door control or

wire shorted.

Safety Sensors
slightly misaligned
(dim or flashing LED).

Motor overheated or

possible RPM sensor

failure. Unplug to reset.

Motor Circuit Failure.
Replace Receiver
Logic Board.

Symptom: One or both of the Indicator lights on the safety sensors do
not glow steady.
Inspect sensor wires for a short (staple in wire), correct wiring polarity

(biack/white wires reversed), broken or disconnected wires, replace/attach

as needed.

• Disconnect all wires from back of motor unit.
• Remove sensors from brackets and shorten sensor wires to 1 -2 ft (30-60 cm)

from back each of sensor.

• Reattach sending eye to motor unit using shortened wires. If sending eye

indicator light glows steadily, attach the receiving eye.

• Align sensors. If the indicator lights glow replace the wires for the sensors. If

the sensor indicator lights do not light, replace the safety sensors.

Symptom: LED is not iit on door controi.
Inspect door control/wires for a short (staple in wire), replace as needed.
• Disconnect wires at door control, touch wires together. If motor unit activates,

replace door control.

• If motor unit does not activate, disconnect door control wires from motor unit.

Momentarily short across red and white terminals with jumper wire. If motor
unit activates, replace door control wires.

Symptom: Sending indicator light glows steadily, receiving indicator light
is dim or fiashing.
• Realign receiving eye sensor, clean lens and secure brackets.
• Verify door track is firmly secured to wall and does not move.

Symptom: Motor has overheated; the motor unit does not operate or
troiiey is stuck on stop bolt = Motor unit hums briefiy; RPM Sensor =
Short travel 6~8" (15-20 cm).
• Unplug unit to reset. Try to operate motor unit, check diagnostic code.
• If it is still flashing 5 times and motor unit moves 6-8" (15-20 cm), replace RPM

sensor.

• If motor unit doesn’t operate, motor unit is overheated. Wait 30 minutes and

retry. If motor unit still will not operate replace logic board.