Vertical – Carrier 38AN User Manual

Page 9

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Table 5 — System Piston Guide and

Refrigerant Charges

UNIT

INDOOR

PISTON

SIZE

OUTDOOR

PISTON

SIZE

REQUIRED

SYSTEM

CHARGE

(lb)*

Indoor

Outdoor

40QNB009

38AN009

Capillary Tube Capillary Tube

1.50

40QNB012

38AN012

Capillary Tube Capillary Tube

1.80

40QNE009

38BK009

32t

30t

1.50

40QNH012

38BK012

42t

42t

2.00

'Charge is based on 25 ft of interconnecting tubing. Charge may need

to be added for longer tubing runs or when used with certain fan
coiis. Check unit namepiate for required charge. This is a totai sys­
tem charge.

tNon-serviceabie Aeroquip piston.

POSSiBLE PIPiNG DIRECTIONS

PREPUNCHED HOLES

BOTTOM/REAR
PIPING

as" MAX (FOR COOLING ONLY AND
HEAT PUMP SYSTEMS)

UNIT

GROUND-LEVEL

INSTALLATION

ROOFTOP

INSTALLATION

Fig. 6 — Maximum System Line Lengths

Step 4 — Mount Outdoor Section

1. If outdoor section is to be installed at ground level, mount

on a solid, level support pad one in. longer and one in.

wider than the outdoor section dimensions.

2. Provide sufficient clearance for airflow, wiring, refriger­

ant piping, service and maintenance. Provide a minimum
clearance of 2 ft from obstructions in front of outdoor
section, 2 ft on outdoor coil side, and 2

’/2

ft on electrical

and piping side. If more than one outdoor section is in­
stalled, provide a minimum clearance of 2 ft between sec­
tions. Position outdoor section so that water or ice from

roof cannot fall directly on unit.

NOTE: The outdoor section can be installed higher than,
lower than, or level with the elevation of the indoor
section. If outdoor section is mounted higher than the in­
door section, the

vertical

distance between the

2

units

should not exceed 30 ft. If the outdoor section is installed
lower than indoor section, the

vertical

distance between

the units should not exceed 16 ft. See table below:

MAXIMUM DISTANCE BETWEEN OUTDOOR UNITS

Outdoor Section Higher

30 Ft Maximum

Than Indoor Section

(Vertical)

Outdoor Section Lower

16 Ft Maximum

Than Indoor Section

(Vertical)

NOTE: Maximum system piping length between indoor and outdoor
units is 35 ft.

Fig. 5 — Fan Coil Unit Refrigerant Piping

Fig. 7 — Fan Coil Unit Bracket Mounting (Size 009 Shown)

Advertising
This manual is related to the following products: