8. Install new natural gas pilot orifice (silver, 1/2-in. long,

0.018-in. orifice diameter).

9. Reinstall pilot gas supply tube bn pilot. When tighten­

ing pilot tube, use backup wrench and turn pilot so
that it will be on the same angle as before.

Do not

rein­

stall pilot at this time.

B. Installation of Main Burner Orifices

1. Remove secondary air shield.

2. Remove main burners from manifold.
3. Remove and discard No. 55 (or field-installed per local

application) orifices from manifold.

4. Install No. 45 main burner orifices provided in kit.

Finger-tighten orifices at least one fxill turn so as not to
cross-thread, then tighten with wrench. There are
enough orifices in each kit for the largest furnace. Dis­
card extra orifices.

The full input rating with No. 45 main burner natural gas
orifices is approved for altitudes up to 2000 ft. The input
rating for altitudes above 2000 ft must be reduced by 4%
for each 1000 ft above sea level. Consult the current edition
of the National Fuel Gas Code NFPA No. 54/ANSI Z223.1,
Part 8.1 and Appendix F Table F-4, for input adjustment

for high altitude.

5. Install new burners with N0^ reduction screens on

manifold. See Figs. 2 and 3 for proper orientation of
burners and pilot.

6. Reinstall pilot assembly.
7. Reconnect pilot supply tube to gas valve.
8. Reconnect electrode wire to spark generator.
9. Reinstall secondary air shield.

C. Conversion of Gas Valve and Inlet Gas Pressure
Check

1. Remove regulator seal cap. See Fig. 4 for BDP 646A or

Fig. 5 for White-Rodgers 36E Gas Valve.

2. Remove adjustment screw and propane gas regulator

spring (red for 646A and white for 36E).

3. Install proper natural gas regulator spring (silver) pro­

vided in kit, in proper gas valve. See Table 1.

4. Replace regulator adjustment screw.

Do not

reinstall

regulator seal cap at this time.

5. Remove 1/8-in. pipe plug from inlet pressure tap on gas

valve.

REGULATOR

A88463

Fig. 2—Pilot/Burner Relationship

-REGULATOR

SEAL CAP

Fig. 3—Position of Pilot Electrode to Pilot

Fig. 5—White-Rodgers Model 36E Gas Valve