6. Check inlet natural gas pressure.

NOTE: This kit is to be used only when inlet gas pressure is

between 4.5- and 13.6-ins. wc.

a. Attach manometer at inlet pressure tap on gas sup­

ply side of furnace gas valve.

A CAUTION

Do not operate furnace more than one minute to check
inlet gas pressure as conversion is not complete at this
time.

b. Set room thermostat “call for heat.”

c. Turn gas supply manual shut-off valve on.

d. Turn furnace gas valve control knob to ON.

e. Turn electrical supply to ON.

f. When main burners have ignited, confirm proper

inlet gas pressure.

g. Turn furnace gas valve control knob to OFF.
h. Turn gas supply manual shut-off valve off.

i. Turn electric supply to furnace to OFF.

j. Remove manometer and replace plug in pressure

tap.

NOTE:

Use propane gas-resistant pipe dope. Do not use

Teflon tape.

7. Attach gas control conversion label P/N 310148-302 to

cell panel.

8. Attach conversion rating plate P/N 310168-312 near

existing rating plate. See Fig. 1.

D. Check Furnace Operation and Make Necessary

Adjustments

1. Be sure main gas and electric supplies to furnace are

off.

2. Attach manometer at manifold pressure tap on down­

stream side of gas valve.

3. Set room thermostat to “caU for heat.”

A WARNING

Never use a match or other open flame to check for

leaks. Use a soap-and-water solution. A failure to heed
this warning could result in personal injury or death.

4.

5.

6

.

Turn gas supply manual shut-off valve on and check

inlet pressure tap plug for leaks.

Turn furnace gas valve control knob to ON and check
all threaded pipe connections for gas leaks.
Turn on electrical supply.

7. When pilot ignites, check pilot gas-supply tube connec­

tions for leaks. When main burners ignite, check mani­
fold orifices for gas leaks.

8. Determine gas input:

a. Turn off all other gas appliances and pilots.

b. Measure time (in seconds) for gas meter test dial to

complete one revolution.

c. Refer to Table 2 for cubic ft of gas per hour.

d. Multiply cubic ft/hour by Btu cubic ft. Obtain heat­

ing value from local gas utihty.

NOTE:

Be sure heating value of gas used for calculations is

correct for your altitude. Consult local gas utility for alti­
tude adjustment of gas heating value.

High altitude:

The full input rating with No. 45 main burner natural gas
orifices is approved for altitudes up to 2000 ft. The input
rating for altitudes above 2000 ft must be reduced by 4%
for each 1000 ft above sea level. Consult the current edition
of the National Fuel Gas Code NFPA No. 54/ANSI Z223.1,
Part 8.1 and Appendix F Table F-4, for input adjustment
for high altitude.

e. Refer to unit rating plate for gas input rate. The

measured input must be within 2 percent of the rat­
ing plate input.

EXAMPLE:

Btuh heating input = Btu/cubic ft times cubic ft/
hour
Heating value of gas = 1070 Btu/cubic ft.
Time for one revolution of 2-cubic-ft dial = 72

seconds
Gas rate = 100 cubic ft/hour (from Table 2)

Btu heating input = 1070x 100 = 107,000 Btuh

9. To adjust input rate:

a. Remove cap that conceals adjustment screw for gas

valve regulator.
Turn adjustment screw either counterclockwise

(out) to decrease input or clockwise (in) to increase
rate. When adjusting input rate, do not set manifold

pressure above 3.8 or below 3.2-ins. wc. Make

any major adjustments by changing main burner

orifices.

b.

Table 2—Gas Rate (Cubic Ft/Hour)

Seconds

SIZE OF TEST DIAL

Seconds

SIZE OF TEST DIAL

for One

1

2

5

for One

1

2

5

Revolution

cu ft

cu ft

cu ft

Revolution

cu ft

cu ft

CU ft

10

360

720

1800

50

' 72

144

360

11

327

655

1636

51

71

141

355

12

300

600

1500

52

69

138

346

13

277

555

1385

53

68

136

340

14

257

514

1286

54

67

133

333

15

240

480

1200

55

65

131

327

16

225

450

1125

56

64

129

321

17

212

424

1059

57

63

126

316

18

200

400

1000

58

62

124

310

19

189

379

947

59

61

122

305

20

180

360

900

60

60

120

300

21

171

343

857

62

58

116

290

22

164

327

818

64

56

112

281

23

157

313

783

66

54

109

273

24

150

300

750

68

53

106

265

25

144

288

720

70

51

103

257

26

138

277

692

72

50

100

250

27

133

267

667

74

48

97

243

28

129

257

643

76

47

95

237

29

124

248

621

78

46

92

231

30

120

240

600

80

45

90

225

31

116

232

581

82

44

88

220

32

113

225

563

84

43

86

214

33

109

218

545

86

42

84

209

34

106

212

529

88

41

82

205

35

103

206

514

90

40

80

200

36

100

200

500

92

39

78

196

37

97

195

486

94

38

76

192

38

95

189

474

96

38

75

188

39

92

185

462

98

37

74

184

40

90

180

450

100

36

72

180

41

88,

176

439

102

35

71

178

42

86

172

429

104

35

69

173

43

84

167

419

106

34

68

170

44

82

164

409

108

33

67

167

45

80

160

400

110

33

65

164

46

78

157

391

112

32

64

161

47

76

153

383

116

31

62

155

48

75

150

375

120

30

60

150

49

73

147

367

Advertising