PREPARATrON

1. Use the dimensional drawings (Refer to FIGURES 1 - 3) to lay

out the range hood’s mounting holes, wiring access and ductwork
by marking the cabinet bottom and drywall where applicable.

2. Make cutouts for wiring and ductwork.
3. If the hood is to be ducted, install the ductwork so that is flush to

the range hood’s mounting surface.

Refer to FIGURE 1 if the range hood is to be installed with a

horizontal discharge.

Refer to FIGURE 2 and FIGURE 3 if the range hood is to be

installed with a vertical discharge.

4. Run two-conductor wire (with ground) from a power source to

the hood location. Bring approximately 12”of wiring through wir­
ing hole in cabinet.

5. Drill four 3/52” diameter pilot holes at points where mounting

holes are marked in cabinet bottom.

6. Insert four (4) mounting screws, leaving approximately W” of

thread exposed.

7. Remove and retain the mounting screws securing the 3W”x 10”

and 7" duct transitions to the hood. Install the appropriate duct
transition as described in the installation section.

INSTALLATION

1. Remove the necessary duct opening and wiring knockout from

the range hood.

If the range hood is to be installed as a non-ducted unit, re­
move the wiring knockout only.

If the range hood is to be installed as a ducted unit, a baffle

plate is provided to close off the non-ducted vent. InstaU baffle

plate (Refer to FIGURE 4) by sliding into place behind grille. Use

locator bumps to orient in grille.

2. For 7" round discharge instaUation, refer to FIGURE 5. Secure

7" adapter (included) to top of hood using screws provided. In­

stall 7” round damper (Model BP87, purchased separately).

For 3W” X 10’ vertical discharge installation, refer to FIGURE 6. Se­
cure 3W” X 10” transition (if used) to top of hood.
For 3W” X 10” horizontal discharge instaUation, refer to FIG­
URE 7. If using the supplied 3W" 10” duct transition, remove the

damper flap from the transition to prevent possible venting inter­

ference. Position transition into wall cutout. Note:The transition
does not festen to the hood.

'

3. Feed the wiring through the access hold and into the electrical

box.

4. Align hood’s keyhole mounting slots over the four (4) partially

installed screws.

5. Making sure the duct positions over the hood's duct transition,

push the hood against the rear wall. Secure hood by tightening
screws.

6. Using a long blade screwdriver, reach into the discharge opening

and make sure the damper flap operates freely (vertical discharge
only).