Sears 919.17632 User Manual

Page 5

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

HAZARD

SAFEGUARDS

Toxic Vapors

Compressed air from Ihfs unit

may

con^in

poisonous

carbon

monoxide.

Never directly inhale the compressed air

produced by this unit.

Certain

sprayed

materials

such

as paints, weed killer, sand, in­
secticides, etc., may be harmful if

used in a closed area or if inhaled.

Be certain to read labels when spraying
paints or poisons.

Use a mask or respirator whenever thera is a

chance that you might inhale anything that
you are spraying. Read all instructions so
that you know that your mask will protect you
from what you are spraying.

Compressed Air

Compressed air may propel dirt,

metal shavings, etc. and result in

possible injury.

Never point any nozzle or sprayer lowanl a
person or any part of the body.

Always wear safety goggles or glasses when
spraying.

SPEaFlCATION CHART

Model No.

919.176210

919.176311 .

919.176320

919.176330

HP

1

1

2

3

Displacement CFM

9.2

9-2

11.7

14XÌ

Bore

2%"

2%"

2%"

Z%"

Stroke

2"

2"

2"

2"

Voltage-Single Phase

'110-220

’110-220

220-240

220-240

Branch Circuit Min. Requirements

20 amp

15 amp

15 amp

15 amp

’Fuse Type

“Fusetran" Type T

"Fusetron’TypeT

"Fusetron" Type T

"Fusetron" Type T

Amperage at Max Pressure

19.5

15.5

12.4

14.4

Air Tank Capacity

12 gal

12 gal ASME

20 gal ASME

30 gal ASME

Approximate Cut-in Pressure

-80' psig

80 psig

100 psig

100 psig

Approximate Cut-out Pressure

100 psig

100 psig

125 psig

125 psig

SCFM at 125 psig

6.4

75

too psig

5.6

5.6

90 psig

6.0

6.0

7.5

8.5

40 psig

7.3

73

9.0

10.3

*Models9l9.i76210&9Tai76311,

1

HP motor is duai voltage, 110-120 and 220-240 vott. It is wired forllO-120 volt but can be converted to

220-240 volt operation. Instructions for connecting the motor for operation at 220-240 volt can be found printed on the Inside of the

motor cover or on the nameplate of motor.

*A circuit breaker is also acceptable.

CAUTION

MCH3EL #91^176311 (1 HP) efr Compressor ean be oper­

ated on a IS amp efreult provided the following conditions
exist:

1) Voltage supply to circuit is normal,

2) Circuit Is not utmd to supply any other electrical needs

(appliances, lights, etc,)

3) Extension cords comply with speclflcatlona in manual.
4) Circuit Is equipped with 15 №ip circuit breaker or 15

amp 'Tusetron” Type T time delay fuse.

If any of the above conditions cannot be met or If ttie

operation of the compressor repieatedly cause Interrup­
tion of the poviwr It msy be necessary to operate It from a

20 amp circuit.

CAUTION

Vivien converting 1 HP models to 220-240 volt operation,
the attached three-prong

110-120

volt plug must be

replaced with a three-prong 220-240 volt plug (purchase
locally) or order line cord Part No. SUOL-404-1.

SCFM (Standard Cubic Feet per Minute);

Unit of measure of air delivery

PSIG (Pounds per Square Inch Gauge):

Unit of measure of pressure