ELECTRICAL

A. Disconnect power before working on pump, motor, pressure switch, or wiring.

Motor Switch Settings

If the motor can operate at either 115 or 230 volts, it is set
at the factory to 230 volts. Do not change motor voltage
setting if line voltage is 230 volts, or if you have a single
voltage motor.

NOTICE: Never wire a 115 volt motor to a 230 volt line.

Remove Motor End Cover

Figure

4 -

Removing Motor End Cover

You will need to remove the motor end cover to change
the voltage setting. The illustration above also shows the
pressure switch. If the power supply connection still
needs to be made, the pressure switch cover will need to
be removed.

Your motor terminal board Gocated under the motor end
cover) should look like the one at right.

Dial Type Voltage Selector

Figure 5 - Voltage Set To 230 Volts, Dial Type

To change to 115 volts;

1. Make sure power is off.

2. Turn the dial counter<lockwise until 115 shows in the

dial window.

3. Reinstall the Motor end cover

4. Go to Wiring Connections, Page 6.

A WARNING Hazardous voltage. Can shock, bum, or

kill. Connect ground wire before connecting power
supply wires. Use the wire size (including the ground
wire) specified in the wiring chart. If possible, connect
the pump to a separate branch circuit with no other appli­
ances on it.

A WARNING

supply line.

Explosion hazard. Do not ground to a gas