OPERATION

WHEN TO EMPTY RECOVERY TANK

See Figure 9

During normal operation, your cleaner may stop recovering
solution from your carpet. When this occurs there are three

check points to alert yoti:

1. An increase in motor noise.
2. No solution visibly being recovered by the floor nozzle.

3. No air coming from the exhaust port of your cleaner,

When this occurs;

1. The Recovery Tank is full and the Float Valve in the

Recovery Tank has been activated. The Recovery Tattk
should be emptied.

— or “

2.

The Recovery Tank has foam in tlte Tank and the Float

Valve has been activated.

NOTE: If cleaner is accidently turned over while in operation,

the float may activate and shut off the suction. If this occurs,
set the cleaner upright. Turn Power Switch "OFF" and let
motor come to a complete stop. Then turn switch back on and

continue cleaning.

TO EMPTY RECOVERY TANK

See Figure 10

1

.

1.

3.

4.

5.

6

.

7.

8

.

9.

Turn Power Switch "OFF" and Disconnect Power Cord
from Electrical Outlet.
Disconnect Short Cord located between Solution Tank
and Recovery Tank.
Disconnect Vacuum Hose by depressing the Lock Button
and remove.
Twist Solution Tube Quick DisconnectNut counterclock­
wise; lift and remove from Quick Disconnect Valve (See
DETAIL "A").
Lift Latches on Power Head.
Lift power Head, by Handle, and remove from Recovery

Tank.

Rotate Metal Latch on the Solution Tank and lift Recovery

Tank from tire Solution Tank.
Empty Recovery Tank.
Reassemble cleaner and resume cleaning. NOTE: Power
Head is designed to go on in only one position. Make sure
the word "VACUUM" on the Power Head is lined up
directly over tlte Hose Inlet on Recovery Tank as shown in
Fig. 10 or Power Head will not seal to unit properly.

QUICK

DISCONNECT

NUT

QUICK

DISCONNECT

VALVE

RECOVERY

TANK

DETAIL "A

SOLUTION

TUBING

POWER HEAD

HANDLE

ALIGN

VACUUM"

OVER

HOSE
INLET

SHORT

CORD

LATCH

SOLUTION

TANK

Advertising
This manual is related to the following products: