MAINTENANCE

DISASSEMBLY AND

ASSEMBLY OF PUMP

IA WARNING iRjsk of electric shock. Ground unit and

disconnect

power

before

attempting

any

work

on

pump or motor.

Your Sears pump is designed for ease in servicing. Should
repair or replacement of the motor or seal be needed, the

pump and piping do not need to be disconnected or dis­
turbed.

1. Disassemble pump as follows:

A. Disconnect power.
B. Drain pump by opening drain cock. Remove pressure

switch tubing from fitting on top of pump.

A WARNING

. To avoid serious injury, release all

pressure from system before attempting to remove
clamp from pump.
C. Remove clamp, Key No. 10, Page 12.
D. Remove pump base mounting bolts. Motor assembly

and back half assembly of pump can be pulled away
from front half.

E. Remove “O” rings.

2. Reassembly of pump.

A. Clean “O” rings and “O” ring grooves.
B. Lubricate “O" rings with petroleum jeUy, and place in

grooves.

C. Slide pump halves together.
D. Clean inside of clamp. Place clamp around pump

halves. Alternately tighten clamp screw and tap clamp
around outside with plastic mallet. This wiR insure

proper seating of “O” ring and clamp.

E. Assemble base mounting bolts. Connect pressure

switch tubing and close drain cock.

F. Prime pump and turn on power.
G. Check for leaks.

Removing Motor for Service

and Replacing Shaft Seal

If it is necessary to separate motor and seal plate, always re­
place the shaft seal. We suggest you purchase this item,
U109-6A, and have it on hand for future use.
NOTICE: The seal consists of two parts, a rotating member
and a ceramic seat. The surfaces of the seal are easily dam­

aged. Read instructions carefully.

1. Disassemble pump per instructions above.

2. Remove diffuser and impeller as follows (Key Nos. 8 and

9, Page 12).

A. Remove screws holding diffuser.

B. Loosen two screws and remove motor canopy from

motor.

C. Place 7/16" open end wrench on motor shaft flat,
D. Turn impeller counterclockwise when facing it.

3. Remove pump back half from motor by unscrewing four

(4) nuts. Pry back half off motor by inserting two (2)

screwdrivers between the back pump half and the motor

flange. This will force rotating portion of seal off shaft.

See Figure 7.

4. Place back half of pump on flat surface and tap out ce­

ramic seat. See Figure 8.

479 0194

Figure 8

5. Clean seal cavity.

6, Install new seal.

A. Clean polished surface of ceramic seat with clean

cloth.