DO NOT INSTALL YOUR DRYER:

1.

In

an

area

exposed

to

dripping

water

or

outside

weather

conditions.

In an area where it will conne in contact with curtains, drapes,

or

anything

that

will

obstruct

the

flow

of

combustion

and

ventilation air.

On carpet. Floor

MUST be

solid with a maximum slope of 1

inch (2.54 cm).

INSTALLATION IN RECESS OR CLOSET

1. A dryer installed in a bedroom, bathroom, recess or closet,

MUST be

exhausted outdoors.

2.

No other fuel

burning appliance shall

be installed in the

same closet as the Gas dryer.

Your dryer needs the space around it for proper ventilation.

DO NOT INSTALL YOUR DRYER IN A CLOSET WITH A
SOLID DOOR.

3.

4.

A

minimum

of

120

square

inches

(JlA.l

square

cm)

of

opening, equally divided at the top and bottom of the door,

is

required.

Air

openings

are

required

to

be

unobstructed

when a door is installed. A louvered door with equivalent

air openings for the full length of the door is acceptable.

MINIMUM INSTALLATION CLEARANCES (Inches)

FRONT SIDES REAR TOP

Alcove

0 (0 cm) 0 (0 cm) 0 (0 cm) 15 (38.1 cm)

Closet

1 (2.54 cm) 0 (0 cm) 0 (0 cm) 15(38.1 cm)

Closet

door

ventilation

required:

2

louvered

openings

each

60

square inches (387 square centimeters) — 3 inches (7.6 cm)

from bottom and top of door.

THIS DRYER MUST BE EXHAUSTED OUTDOORS.

5. The following illustrations show minimum clearance

dimensions for proper operation in a recess or closet

Rigid

Metal

Only

Rigid

Metal

Only

Rigid

Metal

Only

Correct

Correct

6

Correct