Operation of your opener, The key switch or keyless entry, The lockout feature – Sears CRAFTSMAN 139.53640SRT User Manual

Page 32: To open the door manually, Lockout position, Operation of the deluxe, Lighted console wall control, Lock feature

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Operation of Your Opener

Activate the opener with any of the foiiowing
devices:

1. The 3-Function Remote controi. Hold large

push

button down until the door starts to move,

2. The Wall Control. Hold push bar down until the

door starts to move.

3. The Key Switch or Keyless Entry.

When the Opener is Activated:

1. If open, the door will dose. If closed, it will open.

2. If closing, the door will reverse.

3. If opening, the door will stop (allowing space for

entry and exit of pets and for fresh air).

4. If the door has been stopped in a partially open

position, it will close.

5. If obstructed while closing, the door will reverse.

6. If obstructed while opening, the door will stop.

7. The garage door will reverse in the closing cycle

when the invisible beam is broken. If fully open, the
door will not close when the beam is broken. The
sensor has no effect in the opening cycle.

If the sensor is not installed, or not aligned correctly,

the door can't close from any portable remote control.

It can be closed with the Wall Control, the Key
Switch, or the Keyless Entry, however, by pressing

and holding \.he

push bar until down travel is

complete. If you release the push bar too soon, the
door will reverse.

The opener lights will blink for 5 seconds

when the

safety reversing sensor causes the door to reverse.

Opener Lights will turn on under the following
conditions: When the opener is initially plugged in;
when the power is interrupted; when the opener is
activated. They will turn off automatically after 4-1/2

minutes or provide constant light when the Light

feature is activated. Bulb size is 75 watts maximum.

Weak or broken springs could allow an open

door to fall (either rapidly or unexpectedly),
resulting in serious injury, death or property
damage. If possible, use the emergency
release rope and handle only when the door is

fully closed.

(Pull Down)

Manual disconnect

position

The lockout feature
prevents the trolley from
reconnecting automatically.

Pull the emergency handle

down and back (toward the
opener). The door can then
be raised and lowered
manually as often as
necessary. To disengage
the Lockout Feature, pull
the emergency handle
straight down. The trolley
will reconnect on the next

UP or Down operation.

To open the door
manually:

The door should be

fully closed if possible.

Pull down on the red

emergency release
handle and lift the door
manually. To
reconnect the door to
the opener, press the
Wall Control push bar.

Release Arm

Trolley

Emergency

Release Handle

(Pull Down & Back

Towards Opener)

Lockout position

Operation of the Deluxe

Lighted Push Bar

Press to open or close the door.

Press again to reverse

the door during the closing

cycle or to stop

the door while it's opening.

Light Feature

Press the Light button. If the opener lights are off,

they will turn on.

If the opener lights are on,

(even in the 4-1/2 minute

automatic cycle) they will turn off

But if you use the Light button to turn the lights on

and then activate the opener, the lights will turn off
after 4-1/2 minutes.

The Light button will not control the opener lights

when the door is in motion.

Lighted Console Wall Control

Lock Feature

The Lock feature is designed to prevent operation of
the door from portable remote controls. However, the
door will open and close from

the Wall Control push

bar, the Key Switch and the Multi-Function Keyless
Entry.

To Activate:

Press and hold the Lock button for 2 seconds. The
push bar light will flash as long as the Lock feature
is on.

To turn off:

Press and hold the Lock button again for

2 seconds.The push bar light will stop flashing.

Normal operation will resume. The Lock feature will

also turn off whenever the "SRT" button on the
opener end panel is activated.

32

Advertising