ELECTRICAL

Disconnect power before working on pump, motor, pressure switch, or wiring.

Motor Switch Settings

Dial Type Voltage Selector

If the motor can operate at either 115 or 230 volts, it is set at the
factory to 230 volts. Do not change motor voltage setting if line

voltage is 230 volts, or if you have a single voltage motor,

NOTICE: Never wire a 115 volt motor to a 230 volt line.

Remove Motor End Cover

Figure 4 — Removing Motor End Cover

You will need to remove the motor end cover to change the volt­

age setting. The illustration above also shows the pressure

switch. If the power supply connection still needs to be made,
the pressure switch cover will need to be removed.

Your motor terminal board (located under the motor end cover)
should look like the one at right.

Figure 5 - Voltage Set To 230 Volts, Dial Type

To change to M 5 volts:

1. Make sure power is off.

2. Turn the dial counter-clockwise until 115 shows in the dial

window.

3- Reinstall the Motor end cover

4. Go to Wiring Connections, Page 6.

AWARNING

Hazardous

voltage.

Can

shock,

bum,

or

kill.

Connect

ground

wire

before

connecting

power

supply

wires. Use the wire size (including the ground wire) speci­
fied in the wiling chart. If possible, connect the pump to a sep­

arate branch circuit with no other appliances on it.

AWARNING

ply line.

Explosion hazard. Do not ground to a gas sup-