Sears 625.34929 User Manual

Page 11

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

CAUTION: DO NOT TRY TO DO ANY
WIRING IF YOU DO NOT KNOW ELEC­
TRICITY, CALL A GOOD ELECTRICIAN

CAUTION: DO NOT DO ANY WIRING ON

LIVE CIRCUITS. ALWAYS TURN OFF THE
ELECTRICAL POWER AT THE SOURCE,

NOTE: All wiring mustfollow local or national

electrical codes,

1, Looking at FIG. 7 and 8 or 9, install and wire

in a duplex, 3-prong, 115 volt grounded
outlet. Be sure to connect the outlet through
the well pump pressure switch so the solution
pump runs only when the well pump is on,,

CAUTION: Many well pumps work on 230

volts. DO NOT CONNECT THE SOLUTION

PUMPTO A 230 VOLT CIRCUIT. Connect to

only 1 leg of a single phase 230 volt circuit, as
shown in FIG 9.

2, Turn on the electrical power at the source. DO
NOT plug in the power cord this time. First, fill

the storage tank with solution (page 12),

3

is:

§EIG^7

m

115 VOLT OUTLET

; FIG. 8

WIRING DIAGRAM - 115 VOLT SYSTEM

115V

FIG. 9

WIRING DIAGRAM - 230 VOLT SYSTEM

Solution Pump Solution

Power Cord

Pump

11