FILL THE TANK WITH SOLUTjpE

3. Turn the relief-release valve (clockwise only

FIG, 11, page 12} to the open position. Solution is

pumped through the suction tubing, into the pump
head, then returned to the tank (takes 3-5 minutes).

4. When you see solution returning to the tank (look
through fill hole), close the relief-release valve turning

clockwise only. The pump head is primed and will
begin to pump solution out the discharge.
5. When the discharge tubing is filled with solution,
turn the feed control knob to No. 4 and close the
faucet opened in Step 1
6. After 24 hours, check the chlorine residual and the

pH following the guides on pages 12 and 13.

CONTROLS AND FEATURES^

WW THEY WORK

RELIEF-RELEASE VALVE — The solution dispens­
ing system will pump solution into water systems
having up to 100 psi pressure. If the water system
pressure goes over 100 psi, the relief-release valve
opens to protect the dispensing system from

possible damage. When open, solution passes

through the relief-release valve and returns to the

solution tank instead of going to the discharge

tubing (FIG. 12). The relief-release valve closes

and solution again pumps into the discharge
tubing when the water pressure drops to 100 psi

and below.

PRIMING THE HEAD — The relief-release valve
also makes it easy to prime the pump head. With
the solution tank full of solution, and the well

pump and solution pump running, open the relief­
release valve (turn clockwise only). When you see
solution returning to the tank (look through fill
hole), close the relief-release valve. The pump head

is primed and will begin to pump solution out the

discharge tubing.