Icemaker Water Line
Installation Requirements

You will need a shutoff valve, two

1 /4" O D. compression rruts, two

compression sleeves ond enough

1 /4" O D copper tubing to connect

refrigerator to water source (Your

Sears Store or Catalog Sales Office
has a kit available with a saddle-
type shutoff valve and copper
tubing. Before purchasing, make
sure a saddle-type valve complies
with your local plumbing codes |

CAUTION: Do noHnstali icemaker
tubing in areas where temperatures
fall below freezing.

1. Find Cl 3/8" to 1" vertical COLD

water pipe near the refrigerator

When it is necessary to connect into

a horizontal water pipe, make the
connection to the top or side, rather
than at the bottom to avoid drawing
off any sediment from the water pipe

2* Measure from INLET on rear of

refrigerator to wafer pipe. Add 7

feet to allow for moving refrigerator

for cleaning This is the length of

] /4" O D copper tubing you will

need for the job (length from wafer
valve to water pipe PLUS 7 feet),

Be sure both ends of copper tubing
are cut square

3. Turn OFF main water supply
Turn on nearest faucet long enough
to dear line of water

CAUTION: When using any
electrical device (such as o power
drill) to facilitate installation, be

sure the device is insulated or
wired In a manner to prevent the
hazard of electrical shock

4, Using a grounded drill, drill a

3/16" hole in the vertical cold

woter pipe you have selected.

Typical
ways to

connect
to water
supply

S. Fasten shutoff valve to cold water
pipe with pipe clamp. Be sure inlet
end is solidly in 3/16" drilled hole
in water pipe and washer is under

pipe clamp. Tighten packing nut.
Tighten pipe damp screws carefully
and evenly so washer mokes o

watertight connection, Do not
overtighten or you may crush
copper tubing, especially if soft

copper tubing is used. Now you are
ready to conned the copper tubing

Ó. Slip compression sleeve and
compression nut on copper tubing

as shown above Insert end of
tubing into outlet end squarely as far
as it will go Screw compression nut
to outlet end with adjustable
wrench Do not overtighten . Turn

ON main water supply and flush out
tubing until woter Is dear Turn OFF

shutoff valve on water pipe You are
now rea dy to connect other end of

1 /4" copper tubing to water valve

on bock of refrigerator

-------- »■

Through Hoor
io

basemenf

cold wafer pipe

Under sink fo
cold woler
pipe

7. Your model has a water valve
compression fitting coming through
the rear wall of the refrigerator
Assemble compression nut on

compression fitting as shown above

Insert end of tubing into connector
and tighten compression nut Be sure
end of tubing is square in connector
and is inserted as far as it will go. Do
not overtighten Be sure there is
enough extra tubing (coiled into
three turns of about 10" diameter) fo

allow refrigerator to move out from
wall after installation Secure tubing

in metal clamp at top right corner of
compressor compartment cover.

8. Turn shutoff valve ON TIGHTEN
ANY CONNECTIONS OR NUTS
THAT LEAK

9. Copper tubing may now be
fastened to baseboard

10. Your ice cubes can only be as

fresh-tasting as the water that

produces them ThaTs why it Is a
good idea to purify the water with
a water filter The water filter is an
optional part at extra cost and is
available from the Sears Service
Center, Order Filter No. 978488

and install at the inlet woter tube
connection,

11. Water Pressure Limitations:
Not below (15 PS 1,) or above
(125 P.S,i,), if a problem occurs,
call your Utility Company

IMPORTANT: It may take up to 24
hours for your Icemaker to begin
producing ice

The first few batches of ice cubes
should be thrown away, so that

remaining impurities in the water

line will be flushed out

Through wall

\o

uf¡li^y' room

cold wafer pipe

In Cfowl
ipoce under
house