DE-CARBONIZE MUFFLER

Clean carbon and condensation from spark

arrest muffler every 100 hours of operation.

Remove pipe plug from muffler. Start engine

and let run for about 5 - 10 minutes. Shut

engine

down.

When

muffler

has

cooled,

reinstall pipe plug.

REPLACE FUEL FILTER

Replace In-Line Fuel Filter every 300 hours of

operation, or when obviously clogged. Use
pliers to spread clamps each end of fitter
then slide clamps free of filter ends. Install
new filter with arrow on filter body pointing
away from fuel tank. Retain hose to filter with

hose clamps. Start engine and check for
leaks.

Replace

defective

hoses

or

hose

clamps.

Spark Arrest

Muffler

DE-CARBONIZE ENGINE CYLINDER HEADS

Excessive carbon buiid-up in engine combustion area will rob engine power and result in rough

engine operation. Have carbon deposits removed every 300 operating hours, more often if
operating under a steady load, or whenever cylinder head is removed.

STORAGE

Whenever the alternator is to be idle for longer than 30 days, prepare for storage as follows;

1, Disconnect fuel supply hose from fuel tank filler cap,

2. Start engine and let it run out of gas.
3, Let engine cool.
4, When engine has cooled, remove both spark plugs. Pour 2 or 3 tablespoons of clean engine oil

into each spark plug opening. Crank engine to distribute oil.

5. Store unit in a clean, dry, dust-free area.
6. Before using unit after storage, drain and refill engine crankcase with recommended oil. See
CHANGE OIL, Page 20.