OPERATING INSTRUCTIONS

FOR THE PRO-STAT

THERMOSTAT CONTROL

SPECIAL FEATURES

•All information is saved during power failure or

system shut-down and system returns to last
operating mode when power is restored

•Programmable presets and 24 hour delay timer
•Programmed “soft” transition from high to low fan
•Automatic Pro Clean System
•No batteries required
•Large LCD display
•Temperatures displayed in either °F or °C

System ON/OFF Button

Press the ON/OFF button to turn the cooler on or off. The
last used settings of COOL/VENT, set point, and FAN
(AUTO, HIGH, LOW) will be displayed
FAN Button
Pressing the FAN button will select either AUTO, HIGH,

or LOW fan speeds. In AUTO COOL, the cooler starts on
HIGH when the room temp is 2 °F above the set point
and starts on LOW when the room temperature is 1 °F
above the set point. When the room temperature is 1°F
below the set point, the cooler shuts off. In either HIGH
COOL or LOW COOL the fan runs continuously at the
selected speed until the room temperature reaches 1°F
below the set point.
COOL/VENT Button
Press the COOL/VENT button to turn the cooler media
pump on or off. When in the COOL mode, the last set
point and AUTO fan speed will be displayed. To change

the set point, press the up or down SET TEMP buttons.
To change the fan speed, press the FAN button to
operate on HIGH, LOW or AUTO, if the media pump was
off for 10 minutes, the word “WAIT” will be displayed
indicating pre-wetting of the media. Pre-wetting takes 1
minute followed by 30 seconds of HIGH fan, after which
the fan returns to the appropriate speed. When in VENT,
the fan will start in HIGH. To change to LOW, press the
FAN button. Only HIGH and LOW fan speeds are
available in VENT mode.

TIMER Button
The timer has a maximum of 24 hours of start or stop

delay and is adjustable in 1 hour increments.

To set system STOP delay: Turn the cooler ON and

press the TIMER button. The word “STOP” will be

displayed along with “10 HRS FROM NOW”. To increase
or decrease the delay, use the V or HOURS buttons.
Operating modes can be changed during the delayed
stop time period without affecting the TIMER. Pressing
the ON or TIMER buttons will cancel the delayed stop.
After the delay stop time period, the system will remain
OFF until activated by the user.

To set system START delay: Turn the cooler OFF and

press the TIMER button. The word “START” will be

displayed along with “10 HRS FROM NOW”. To adjust
the start delay, use the “+" or HOURS buttons to
increase or decrease the start delay time. Set the desired
operating mode and fan function.

Changes can be made at any time. Pressing the ON
button will cancel the delay start and turn the cooler ON.
Pressing the TIMER button will cancel the delay start
and the system will remain OFF. After the delay period,

the cooler will turn ON and remain ON until deactivated

by the user.
ROOM TEMP Button
Press the ROOM TEMP button to display room

temperature. The room temperature will be displayed for
6 seconds. The ROOM TEMP function can be used in
any operating mode including system OFF. Note; Due to
the variation in accuracy from one thermostat to the
next, there will be some variation in the room
temperature displayed by different thermostats.
Automatic Pro Clean System
Your cooler is equipped with two LSP-93 “low sump”
pumps. The cooler pump supplies water to the media
and the drain pump dumps the contents of the sump
every 5 hours of media pump operation. The sump
automatically fills with fresh water. The drain cycle is

controlled automatically by the Pro-Stat and the word
“DRAIN” will flash on the display while the drain cycle is
active.

DRAIN Button
Pressing the DRAIN Button will activate the drain pump

for 1 ’/z minutes and cause the timed drain cycle to reset.
The word "DRAiN" will flash on the display. The DRAIN
cycle can be initiated in any operating mode including
system OFF. If the DRAIN cycle is initiated during a
prewet cycle, the word ‘WAIT” will flash on the display,
and the DRAIN cycle will start after the prewet cycle is
completed. The DRAIN button can be used to drain the
cooler at the end of the season by first closing the water
supply to the cooler.

SET