Special functions – Sears AeroCool PD6231 User Manual

Page 8

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

SPECIAL FUNCTIONS

ICWIKSET Presets
Press the KWIKSET button to display the DAY or NITE
preset or to return to the standard display mode. Pressing

the KWIKSET button to either the DAY or NITE preset
causes the set point, FAN and COOL settings to assume
the values stored in memory. Settings for set point, FAN,
and COOL modes are displayed for each preset. The
cooler will then operate with the displayed preset settings

until the user leaves the KWIKSET mode or enters a

different preset.
Change/Save a Preset: Press the KWIKSET button until
the desired preset is displayed. To initiate the edit mode,
press either COOL, FAN, Up or Down buttons. The edit
mode is activated when the DAY or NITE icon is flashing
on the display. Chose the new operating mode (COOL or
VENT), the new set point, and the new FAN mode (AUTO,
HIGH, LOW) with the appropriate buttons. To save the
now settings, press the KWIKSET button. The NITE or
DAY icon will stop flashing indicating that the new
operating modes have been stored in memory.
Save a Preset With Delayed Stop Tinier: Press
KWIKSET until the desired preset is displayed. Enter the
editing mode (press either FAN, COOL, Up or Down
buttons). The NITE (or DAY) icon should be flashing.

Activate the delay timer by pressing TIMER. Set the
desired delay using the “+” or HOURS buttons. Make
any other changes to COOL, FAN, or set point as desired.
Save the changes by pressing the KWIKSET button. The
stop delay is now part of the preset. To remove the stop
delay from the preset, enter the editing mode, press the
TIMER button to turn off the timer, and save the changes.
Save a Preset With Delayed Start Timer:

Press

KWIKSET until the desired preset is displayed. Enter the
editing mode and make desired changes to set point, FAN,
and COOL modes (the NITE or DAY icon will be flashing).
Next, press the ON/OFF button. The control will
automatically set the system OFF and start delay timer

when the edit mode is active. Adjust the start delay time

using the and HOURS buttons. Change any of the

operating modes (COOL, FAN, and set point) as desired.

Press the KWIKSET button to save the preset with start

delay. To remove the start delay from the preset, Press
KWIKSET until the desired preset is displayed, initiate
editing, and press either the ON/OFF or the TIMER button.
The control will automatically be set to ON. Press the
KWIKSET button to save the preset without the start delay.
Advanced Delay Timer
If a preset is saved with a delayed stop, it is possible to set
a delayed start for this preset (this feature only works for
presets with delayed stop). Press the KWIKSET button
until the desired preset (with stop delay) is displayed.
Press the ON/OFF button to turn the system OFF. Press

the TIMER button to activate the start delay and use the
“+” and HOURS buttons to adjust the start delay. The
start delay will count down until the preset is activated and
then the stop delay will count down until the system is
turned OFF. Changes to the operating modes made while
the advanced start delay is active will not affect the preset,
but will be temporarily saved and will be displayed when
the system is turned ON after the preset is finished
running.

Change Scale
To change the temperature scale, press COOL to view
set point. Press and hold the SET TEMP up and down
buttons and release when the displayed temperature
changes from °F to °C or vise versa. The new
temperature scale will remain active until an ERASE
command is issued. Scale change can only occur In

the COOL mode.

Erase Function

The ERASE function will restore all settings to the
factory default values. First, turn the system ON and
hold the ON/OFF button down until ERASE is
complete. Wait for 1 second, and then hold the SET
TEMP up and down buttons down. After about 3
seconds, the number “0.9” will be displayed and will
begin to count down to “0.0”. When the set point of
72.5 °F is displayed, the ERASE function is complete.
Program Differential Value
The differential value is the difference between the turn
off temp and the turn on temp. To change the
differential, press and hoid the ROOM TEMP and SET

TEMP down buttons until the display changes to the

program display. Press the SET TEMP up button to
increase the differential and the down button to
decrease the differential. Press the ROOM TEMP
button to save the new differential. The new differential

will remain active until the ERASE function is executed.
Reset
To perform a control reset, press and hold the timer
buttons (TIMER and both HOURS buttons) until the
display goes blank. Release the buttons and the
display will return to normal. NOTE: If the operating
mode was changed or if a delay timer was set after the
last power up or power failure, the changes will not be
recalled. Only the last saved data wilt be restored.
KWIKSET presets and differential settings will remain
intact. In the event of power failure, delay timer settings
will be maintained for a minimum of 8 hours and up to

15 hours. At the end of the 15 hours, the timers will no

longer be updated. Any remaining time left in the delay

will continue after power is restored.

Advertising