Mounting and wiring the safety reversing sensors, Aligning the safety reversing sensors, Troubleshooting the safety reversing sensors – Sears 139.53930D User Manual

Page 22

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

MOUNTING AND WIRING THE SAFETY REVERSING
SENSORS

• Slide a 1/4"-20x1/2" carriage bolt head into the slot on

each sensor. Use wing nuts to fasten sensors to
brackets, with lenses pointing toward each other across
the door. Be sure the lens is not obstructed by a bracket
extension (Figure 5).

• Finger tighten the wing nuts.

• Run the wires from both sensors to the opener. Use

insulated staples to secure wire to wall and ceiling.

• Strip 7/16" (11 mm) of insulation from each set of wires.

Separate white and white/black wires sufficiently to
connect to the opener quick-connect terminals. Twist
like colored wires together. Insert wires into quick-
connect holes: white to white and white/black to grey
(Figure 6).

ALIGNING THE SAFETY REVERSING SENSORS

• Plug in the opener. The indicator lights in both the

sending

and receiving eyes will glow steadily if wiring

connections and alignment are correct.

The sending

eye amber indicator light will glow regardless

of alignment or obstruction. If the green indicator light in
the receiving eye

is off, dim, or flickering (and the invisible

light beam path is not obstructed), alignment is required.

• Loosen the sending eye

wing nut and readjust, aiming

directly at the receiving eye.

Lock in place.

• Loosen the receiving eye

wing nut and adjust sensor

until it receives the sender’s beam. When the green
indicator light glows steadily,

tighten the wing nut.

Figure 5

TROUBLESHOOTING THE SAFETY REVERSING
SENSORS

1. If the sending eye

indicator light does not glow steadily

after installation, check for:

• Electric power to the opener.

• A short in the white or white/black wires. These can

occur at staples, or at opener connections.

• Incorrect wiring between sensors and opener.

• A broken wire.

2. If the sending eye

indicator light glows steadily hut the

receiving eye

indicator light doesn't:

• Check alignment.

• Check for an open wire to the receiving eye.

3. If the receiving eye

indicator light is dim, realign

either sensor.

NOTE: When the invisible beam path is obstructed or
misaligned while the door is closing, the door will reverse.
If the door is already open, it will not close. The opener
lights will blink 10 times. See page 20.

22

Advertising