Carrier 320720---751 THRU ---761 User Manual

Page 3

Advertising
background image

3

COMBUSTION-AIR

INTAKE

CONNECTION

GAS VALVE

VENT OUTLET

CONDENSATE

TRAP

MOTOR AND

BLOWER

ASSEMBLY

AIR FILTER AND

RETAINER

PRESSURE

SWITCHES

INDUCER MOTOR

AUXILIARY

JUNCTION BOX

CONDENSING

HEAT

EXCHANGER

(BEHIND CELL

INLET PANEL)

BURNER

ENCLOSURE

VENT OUTLET

CONTROL

CENTER

BLOWER

ACCESS PANEL

SAFETY

INTERLOCK

SWITCH

CAP AND

CLAMP

(UNUSED

DRAIN

CONNECTION)

PRIMARY HEAT

EXCHANGER

(BEHIND CELL

INLET PANEL)

A01026

Fig. 1 -- Two--Stage, Two--Speed and Fixed--Capacity

Model(s) in Upflow Orientation

Remove Inducer Assembly

1. If not previously disconnected, disconnect inducer motor

wire connector at quick--connect.

2. If not previously disconnected, disconnect pressure switch

wires.

3. Remove collector box pressure switch tube from pressure

switch.

4. Remove four screws attaching inducer housing to cell pan-

el.

NOTE: Inducer housing, inducer motor, and pressure switch(es)
should be removed as 1 assembly.
Install Primary Cell Inlet Panel

1. Remove four screws attaching condensing heat exchanger

assembly to primary cell inlet panel.

2. Remove screws attaching primary cells to primary cell in-

let panel.

3. Remove main limit and shield from primary cell inlet pan-

el. Note orientation of shield and direction of main limit

for reassembly.

4. Remove primary cell inlet panel by lifting panel off con-

densing heat exchanger collector box.

5. Slide new inlet cell panel over condensing heat exchanger

collector box.

6. Attach primary cell inlet panel to primary cells by doing

the following:

a. Center primary cell inlet panel over primary cell open-

ings.

b. Use an awl to align holes and start ALL screws

(provided in kit) in primary cells.

c. After all screws are started, check position of fiberglass

gasket and tighten screws in cells.

7. Install main limit and shield in primary cell inlet panel.

BURNER
ENCLOSURE

PRIMARY HEAT

EXCHANGER

(BEHIND CELL

INLET PANEL)

GAS VALVE

CAP AND
CLAMP
(UNUSED
DRAIN
CONN.)
INDUCER
MOTOR

VENT
OUTLET

PRESSURE
SWITCHES

BLOWER
ACCESS
PANEL
SAFETY
INTERLOCK
SWITCH

MOTOR AND
BLOWER ASSEMBLY

AIR FILTER

AND RETAINER

CONDENSATE

TRAP

INDUCER

HOUSING

DRAIN TUBE

CONDENSING

HEAT

EXCHANGER

(BEHIND CELL

INLET PANEL)

INDUCER MOTOR

WIRE

CONNECTOR

VENT OUTLET

AUXILIARY

JUNCTION BOX

COMBUSTION-

AIR INTAKE

CONNECTION

CONTROL
CENTER

A93407

Fig. 2 -- Variable--Speed Model in Upflow Orientation

NOTE: Visually check location of main limit and shield to
ensure shield is not touching primary cells. If shield is touching,
short cycling of limit will occur.

8. Reinstall condensing heat exchanger assembly to primary

cell inlet panel.

Reinstall Inducer Assembly

1. Inspect connector box gasket where inducer housing will

mate.

NOTE: If gasket is damaged in any way, it must be repaired. To
repair, apply a small bead of G.E. RTV 162, G.E. 6702, or
Dow--Corning RTV 738 to damaged gasket area. Apply sealant
releasing agent such as PAM cooking spray or equivalent (must
not contain corn nor canola oil, halogenated hydrocarbons or
aromatic content to prevent inadequate sealing) to inducer
housing mating surface.

2. Attach inducer assembly to cell panel by aligning four

screws through inducer housing spacers. Tighten screws to

secure.

3. Attach collector box pressure switch tube to pressure

switch. See tubing diagram of furnace for proper location

attachment.

4. If control was removed from furnace with whole cell panel

assembly, reconnect inducer motor wire connector at
quick--connect.

5. If control was removed from furnace with whole cell panel

assembly, reconnect pressure switch wires. Refer to wiring
diagram on furnace for proper attachment.

Reinstall Burner Enclosure Assembly

1. Position burner enclosure gasket between the burner box

and inlet cell panel and secure burner box on inlet cell
panel using screws removed earlier.

2. Connect pressure tube to gas valve.
3. Inspect gasket, then install intake housing on burner en-

closure.

320720