Warning – Carrier 320720---751 THRU ---761 User Manual

Page 5

Advertising
background image

5

NOTE: Use propane gas--resistant pipe dope to prevent gas leaks
DO NOT use Teflon tape.

EXPLOSION AND FIRE HAZARD
Failure to follow this warning could result in personal

injury, death and/or property damage.
For upflow or downflow applications, gas valve knob

or switch must be facing forward or tipped to the UP

position.

!

WARNING

16. Connect field power supply to J--box.
17. Install blower access panel.
18. Turn on gas and electrical supplies to furnace.
19. Check for gas leaks.

EXPLOSION AND FIRE HAZARD
Failure to follow this warning could result in personal

injury, death, and/or property damage.
Never test for gas leaks with an open flame.

Use a

commercially available soap solution made specifically for

the detection of leaks to check all connections.

!

WARNING

20. Check furnace operation through two cycles.
21. Check for condensate leaks.
22. Replace furnace door.

320720