Electrical Requirements

Electrical Grounding Instructions

This appliance isequipped with a three-prong grounding plug
for protection against possible shock hazards, if a two-prong
wall receptacle is encountered, the customer is required to
contact a qualified electrician and have the two-prong wall

receptacle replaced with a properly grounded three-prong

wall receptacle in accordance with the National Electrical
Code.

Room air cond itioners are designed to operate according to
requirements on the nameplate and as shown in Table 1,
Fuse or circuit breaker ratings must be accord ing to the fuse
instruction label and as shown in Table 1, Do not plug
models marked “Use on Single Outlet Circuit Only” into a

circuit with another appliance or light fixture.

WARNING

To avoid death, persona! injury or property
damage due to electrical shock, this unit
must be grounded. Do not under any
circumstances cut or remove the round
grounding prong from the plug. Do not use
a two-prong adapter.

A

WARNING

To avoid death, personal injury or property
damage due to electrical shock, do not use
an extension cord. Do not pinch the power
cord. Do not remove the warning tag from

the power cord.

Unit Plug Type

Receptacle

Circuit Rating,

Voltage Rating

Required

Breaker or

Time

Delay Fuse

On Unit Nameplate

víüy

125 V-15 AMP

115V

NEMA No. 5*15P

NEMA Nü, 5-15R

©

/"□A

J

250V-15 AM P

230/20SV rated

at 12 amperes or less

NEMA No. 6-15P

NEMA No. 6-15R

Z30/208V rated over

250V-20AMP

12 amperes but not more

NEMA No. 6-20P

NEMA No. 6-20R

than 16 amperes

©

\a ay

250V-30AMP

230/208V rated

at 24 amperes or less

NEMA No. 6-30P

NEMA No. 6-30R

Safety Features

This room air conditioner is equipped with an electronic
control to improve comfort and ensure reliability.

Compressor Lockout

To extend the life of the compressor a three minute time
delay will occur when:

Electrical power is first supplied to the unit

The thermostat is turned down immediately after the
compressor stops running.

The Fan Control is quickly turned from FAN ONLY to
COOLING mode or vice versa.

Low Voltage Protection

This unit is equipped with “brownout” protection. In case
of an extreme brownout, the Amana control will interrupt
power to the unit to prevent compressor failure. When the
line voltage reaches at least 100 VAC, the control will re­
energize your unit.

Note: A compressor lockout will occur after the unit is re­
energized.

Table 1

Advantages of Amana’s Electronic Controls

•Digital Temperature Setting

- Temperature can be set from 60°F to 90°F in 1°F

increments

•Digital Temperature Display

- Shows indoor room temperature in FAN ONLY

mode

- Shows desired temperature setting in other modes

Computer Memory that Remembers

- The unit remembers the last settings used when

last turned on.

•TempAsure'^ Thermostat

- Maintains set temperature within 1.5°F for maxi­

mum comfort

•Smart Cool

•Energy Saver with TempAsure^ air sampling