Component Testing Procedures

 WARNING

To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless
testing requires it.________________ ______________________________

Illustration

Component

Test Procedure

_______________ Results ______________

Indicates continuity with bulb screwed in.
If not replace._________________________

31823701

Oven light socket

Test continuity of receptacle
terminals.

31722801

Oven indicator light
and
Surface indicator light

Remove one lead from switch

terminal and measure resistance

across terminals.

Measure voltage at indicator light.

Switch closed; 0 il

Switch open; Infinite resistance

If voltage is present and light does not

operate. Replace light.

If no voltage is present at indicator light

check wiring._________________________

301491

Rocker switch

Measure continuity of switch

positions;

Closed
Open

Ccmtinuity, if not replace.
Infinite, if not replace.

31734602—1500

W

31734606-^600 W

Coil surface elements
6" and 8"

Test continuity of terminals.

Continuity, if not replace.

31730101

Coil surface terminal

block

Remove element and turn surface

element on and test for voltage at

terminal block.

240 VAC

31794701-1200

W

31794601-1500

W

31794501-2000

W

31794801-2500 W

Ribbon radiant

elements

Remove one wire lead from element

and measure resistance of the
element.

Continuity, if not replace.

1200W: 45 to 51 n

1500W: 36 to 41

Cl

2000W:

27 to 31 Q

2500W: 21 to 25 n

31846201

Ribbon surface

thermal limiter/hot

light switch

Turn surface element on and test for
voltage. See wiring diagram and

schematic.

1a-2a 240 VAC

1b-2b 120 VAC

Disconnect leads and measure

resistance on the foNoviring:

1a-2a room temperature-continuity

1b-2b room temperature-infinite

240 VAC

uwb

A

EtotirovM

q.n

TTl

V‘

■u

a

Th«mwO>Oisc (TOO)

n n

to la

r

Î

trxr

Might

059552

Bake element

Disconnect wire ieads to element and
measure resistance of terminals.

Measure voltage at bake element.

Continuity, approximately 23 Q,

if not replace.

240 VAC, see wiring diagram for terminal

identification.
If no voltage is present at bake element

check wiring.__________________________

061732

Broil element

Disconnect wire leads to element and

measure resistance of terminals.

Measure voltage at broil element.

Continuity, approximately 19 il,

if not replace.

240 VAC, see wiring diagram for terminal

identification.
If no voltage is present at broil element

check wiring.

314907

Oven temperature
sensor

Measure resistance.

Approximately 1100 o at room

temperature 75° F.____________

31891202

Infinite switch

Remove wiring from terminals HI and

H2. Connect Volt ohms meter to

HI and H2.

Measure the following for voltages at

LO, MED, HI;

HI to H2

Time On

LO

5%

MED (4-5)

50%

HI

100%

Time Off

95%

50%

0

%

240 VAC, if not replace switch.