Component Testing Information

A WARNING

To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless

testing requires it.

Illustratiort

Component

Test Procedure

Results

053584

Control limit

Normally Closed

Verify proper operation.

Closed

245°F

Open

275“F

Continuity
Infinite
If open at room temperature, replace.

31715201— LH
31715202— RH

Opening

Hinge

Carefully open the hinge fully, and
insert a wooden dowel or screwdriver

bit into opening.
Remove top and bottom screws

securing hinge.
Slide hinge top towards rear of unit

and guide hinge out through frame

opening or storage drawer.

A CAUTION

Do not place hands in hinge area when

oven door is removed. Hinge can snap
closed and pinch hands or fingers.

065780

Door lock switch

Switch connection in following
positions:

Unlocked
Locked

Set ERC to Clean

COM-NO=Open, COM-NC=Closed
COM-NO=Closed, COM-NC=Open

Lock LED should flash
Lock LED and Oven LEO should
illuminate, If Lock LED does not
illuminate, check switch and wiring.

305797

Door plunger switch

Remove switch from unit and measure

the following points:

C-NC
C NO

Plunger in infinite. Plunger out continuity.

Plunger in continuity, Plunger out infinite.

31797301

Autolatch assembly

with door plunger
switch

Disconnect wires and test for
continuity per diagram.

NC

NC

LI L2 COMI PM

com

!

no

X ■ I' Jr >L i

120 VAC LedVUntocfc

Motor

Door

Switch