Optional accessories, Transport, Inputs and outputs – Tascam DA-88 User Manual

Page 6: Rc-848 full-function remote control unit, Rc-808 basic transport remote control unit, Sy-88 sync board, A pw-88s sync cable, Pw-88d (1 m)/pw-88dl (5 m) dubbing cable, Mu-8824 24-channel meter unit, Pw-88m meter cable

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Specifications

Optional Accessories

Transport

Recording Format

: 4-rotary head digital recording

Tape

: Hi8 video tape

Number of Channels

: Eight plus subcode area

Recording Time

: 108 minutes using P6/E6-120

tape/113 minutes using P5/E5-90 tape

Tape Speed

: 15.9 mm per second

Fast Forward/Rewind Time

: Approximately 80 seconds

using P6/E6-120 tape/85 seconds using P5/E5-90 tape
(100 times play speed)

Shuttle Speed

: 1/4 to 8 times play speed

Inputs and Outputs

Digital I/O

: TDIF (TEAC Digital Interface Format), 25

pin D-sub xl

Analog Input

: 25 pin D-sub connector xl, +4 dBm,

10k ohms (balanced)
RCA jack x8, -10 dBV, 50k ohms

(unbalanced)

Output

: 25 pin D-sub connector xl, +4 dBm,

75 ohms (balanced)
RCA jack x8, -10 dBV, 250 ohms

(unbalanced)

Sync Input

: 15 pin D-sub connector xl

Output

: 15 pin D-sub connector xl

Word Sync Input

: BNC connector xl

Output

: BNC connector x 1

Remote Input

: 8 pin DIN connector xl

Remote Punch In/Out

: 1/4" phone jack xl

Typical Performance

Sampling Rate

: 44.1/48 kHz

Quantization

: 16 bit linear

Pitch Control

: +1-6% in 0.1 % increments

Frequency Response (Record and Play) :

20 Hz to 20 kHz,+/-0.5 dB

Dynamic Range

: Better than 92 dB

Wow and Flutter

: Less than measurable limits

Total Harmonic Distortion

: 0.007%

□ RC-848 Full-function Remote Control Unit
o 99-point autolocator functions
o ACCESSORY 1 and 2 connectors for controlling

TASCAM (or other) audio machines

o RS-422 connector for controlling VT machines

o Jog/shuttle wheel for locating a specific point at variable

speeds

o Keypad-entered time locations
o Menu-selectable controls of the optional SY-88

synchronizer

□ RC-808 Basic Transport Remote Control Unit
Has duplicates of REC FUNCTION, ALL INPUT, AUTO
INPUT,

REHEARSAL,

AUTO

IN/OUT,

CLEAR,

REPEAT, MEMO and LOC in addition to the transport
controls.

□ SY-88 Sync Board
o All SMPTE/EBU time codes supported : Drop 29.97

fps, Non Drop 29.97 fps, 30 fps, 25 fps (EBU), and 24
fps (Film).

o Offset sync with sub-frame accuracy
o Automatic offset entry

a PW-88S Sync Cable
For connecting multiple DA-88s in series when one serves
as the master and others as slaves. One cable establishes
connection between two DA-88s.

□ PW-88D (1 m)/PW-88DL (5 m) Dubbing Cable
For connecting two DA-88s through their digital I/O port
when one serves as the source machine and the other as the
target.

□ MU-8824 24-channel Meter Unit
Allows metering three DA-88s.

□ PW-88M Meter Cable
For connecting the MU-8824 meter unit to the DA-88.

General

Power Requirements :

USA/Canada :

120 V AC, 60 Hz

Europe

: 230 V AC, 50 Hz

U.K./Australia

: 240 V AC, 50 Hz

Consumption

: 74 Watts

Dimensions (WxHxD)

: 482 mm x 176 mm x 377 mm

Weight

: 14 kg

CF Changes in specifications and features may be made

without notice or obligation.

□ IF-88AE Interface Unit
For data communication between the DA-88 and other
digital machines with AES/EBU digital FO or SPDIF.

□ IF-88SD Interface Unit
For data communication between the DA-88 and other
digital machines with SDIF-2.

□ RC-30P Punch-in Footswitch