STEP 8: LUBRICATION OF BEARINGS

CAUTION; DO NOT OPERATE FAN WITHOUT LUBRICATION. SUCH OPERATION

COULD RESULT IN PERMANENT DAMAGE TO THE MOTOR.

Fans are shipped without oil. A one-ounce bottle or tube of high grade SAE 20 oil is packed with fan. To

avoid overflow during filling, add oil very slowly, about 1/4 of the bottle/tube every 10 seconds.

To check oil supply; Bend the end of a pipe cleaner into a 1/2" long hook and insert it into the oil reser­

voir as shown In FIG. 8. if oil touches the pipe cleaner, the fan has ample oiUf it does not touch, add

SAE 20 oil slowly until it just touches pipe cleaner. Under normal use, oil level should be checked once

per year.

STEP 9: OPERATION OF FAN

A.

Turn electrical service on at main panel

B.

Attach pull cord to switch chain. Switch operates in sequence. "High" - "Off" • "Low" • "Off", or "High" • "Low" - "Off".

Pull cord SLOWLY to operate. Also, release the cord SLOWLY so as to prevent cord from flying up into blades, possibly resulting

in damage to blades or injury.

NOTE: DO NOT USE AN ABRASIVE CLEANSER ON FAN. A MILD DETERGENT WILL CLEAN MOST UNITS TO THEIR

ORIGINAL APPEARANCE.

INSTALLATION IN CONCRETE CEILING

FOLLOW BASIC INSTALLATION INSTRUCTIONS. INCLUDING CAUTIONS, MAKING THE CHANGES AS LISTED BELOW.

CAUTION:

A) FOR CONCRETE MOUNTING THE DRILLED HOLE MUST BE AS RECOMMENDED BY THE MANUFACTURER OF THE ANCHOR

(THIS IS USUALLY MARKED ON THE ANCHOR) AND MUST BE DRILLED AT LEAST 1/2" DEEPER THAN THE LENGTH OF THE ANCHOR.

B) THE HOLE MUST BE MADE WITH A SUITABLE CARBIDE TIPPED MASONRY DRILL WITH A TIP DIAMETER CONFORMING TO

ANSI B94.12 ( 5/8" NOMINAL = .660/ .650 ACTUAL)

C) THE ANCHOR MUST BE NEW AND UNUSED.

D) THE CONCRETE CEILING MUST BE SOUND AND FREE OF CRACKS OR VOIDS IN THE VICINITY OF THE MOUNTING HOLE.

E) THE ANCHOR MUST BE HAMMERED IN FLUSH WITH THE SURFACE OF THE CONCRETE.

F) THE HOOK MUST NEVER BE BACKED OUT. IF THE HOOK CAN BE TURNED EASILY ( BY HAND ),

DO NOT HANG FAN.

A. Drill hole In concrete ceiling to receive 3/8 x 2Vz lag screw expansion shield

anchor, "STAR STA2IN"#1825 - 00300 or equal (not furnished). Install shield in

hole observing all cautions above, and thread hook Into shield to depth shown in
Fig. 9. Do NOT back hook out to achieve the 1" dimension.

B. When properly installed, such an anchor wiil hold a proof test load of over 900 lbs.

and is rated for a safe working load of over 240 lbs.

C. Proceed with the installation of the fan per the basic installation instructions.

3n*x21Q'LAQ SCREW

ADDITIONAL WOOD INSTALLATIONS

USE THE SPECIFIC FIGURE BELOW SHOWING THE MOUNTING DESIRED AS

A GUIDE IN CONJUNCTION WITH THE BASIC MOUNTING INSTRUCTIONS.

CONCRETE CEIUNQ MOUNT

HORIZONTAL BEAM MOUNT

MOUNTING ON SPAN SeTWEEN PITCHED SEAMS

PITCHED BEAM MOUNT

Hunter

COMFORT CONDITIONING DIVISION, Robbins & Myers, Inc.

2500 Frisco Ave., Memphis, Tenn. 38114

JRpBBINS

HIVfYERS

FORM NO. 40590 REV. 5 - 8 1