S

hear

B

olts

IMPORTANT; Use only Ariens Shear Bolts for

replacement. Use of any other type of shear bolt may

result in severe damage to unit.

Occasionally a foreign object may enter the auger/

impeller housing and jam the auger, breaking Shear

Bolts (Figure 8) which secure the auger to the shaft. This

allows auger to turn freely on the shaft preventing
damage to gear drive.

For Replacement:

1. Slide auger outward against roll pin and align hole in

shaft with hole in auger (holes in shaft for roll pins
and Shear Bolts line up).

Drive Shear Bolt through hole (if Shear Bolt was
broken this will drive remaining part from shaft).

Secure Shear Bolt with nut.

2

.

3.

T

ire

P

ressure

Maintain the unit tire pressure at a maximum 20 PSI
(138 kPa).

F

riction

W

heel

1. To replace friction wheel, tip unit up onto housing on

a flat level surface.

2. Remove bottom cover by removing four cap screws.

3. Place Speed Selector in first “1” position, depress

Traction Clutch Lever to hold friction wheel and hub.

Release traction clutch lever, remove cap screws
(Figure 9), shift to third "3” position, and remove

friction wheel.

4. Secure new friction wheel on hub with five cap

screws and torque cap screws to 8-10 ft. lbs. (10,6-

13,3 Nm)

5. Replace bottom cover.

6. Adjust Traction Drive Clutch (see Adjustments).

1. Cap Screw

2. Friction Wheel

3. Reduction Shaft Nut
4. Reduction Sprocket

Figure 9

=

A

uger

G

earcase

IMPORTANT: Too much lubricant may cause excessive
leakage. Too little lubricant will cause gear and/or
bearing damage. Proper oil level must be maintained for

operation.

Gear cases are filled to the correct level at the factory.

Unless there is evidence of leakage, no additional
lubricant should be required. Check for evidence of
leakage every 25 hours of operation.

To insure adequate lube level:

1. Remove filler plug. Lubricant must be at least up to

bottom of lube filler hole with unit resting on a level-
surface.

2. Add lubricant (Figure 10), if required. Allow oil to

drain to level of plug and replace plug.

3. Use only Ariens special gear lube L-2 (Part Number

00008000).

Rev. 9/98