Section 2 - Installation

INSTALLATION

Series QP55-G Recreational Vehicle Generator

2.2.5 COMPARTMENT FLOOR CUTOUTS

You must provide openings in the generator com­

partment for the following items (Figure 2.8):

• Engine exhaust and cooling air outlets
• Generator cooling air inlet
• Four holes for passage of generator mounting

bolts. See Section 2.1.4 (Page 23).

DANGER

Fuel lines and exhaust piping must not pene­

trate into

the

vehicle living area.

23 COOLING AND VENTILATING AIR

It is absolutely essential that an adequate flow of
air for cooling, ventilating and engine combustion
be supplied to the generator set. Without sufficient
airflow,

the

engine/generator

quickly

overheats.

Such overheating can cause serious operating diffi­
culties and also may cause fire and personal injury.

The installer must make sure that sufficient air is

available to the generator for cooling, ventilating
and combustion. The installer also must provide for
a path for exhausting the cooling air to the exterior
of a compartment, if so equipped.

Figure

2.8

-

Compartment Floor Cutout

Generac* Power Systems, Inc. 35