Hidden Features

(continued)

Hunter Quick Check

This circuit diagnostic procedure is can quickly identify “shorts”
commonly caused by faulty solenoids or when a bare common
wire touches a bare station control wire.

To initiate the Hunter Quick Check test procedure:
1. Press the j, k, h and i buttons simultaneously. In the

standby mode, the LCD will display all segments (helpful
when troubleshooting display problems).

2. Press the j button to begin the Quick Check test procedure.

The system will search all stations to detect a high current
path through the station terminals. When a field wiring short is
detected, an ERR symbol preceded by the station number will
momentarily flash on the controller LCD display. After the Hunter
Quick Check completes running this circuit diagnostic procedure,
the controller returns to the automatic watering mode.

Clearing Controller’s Memory/Resetting Controller

If you feel that you have misprogrammed the controller, there
is a process that will reset the memory to factory defaults and
erase all programs and data that have been entered into the
controller. Press and hold the n button. Press and release
the

RESET button on the back of the front panel. Wait until the

display shows 12:00 am. Release the n button. The controller
is now ready to be reprogrammed.

NOTE

Any programs that have been saved with Easy Retrieve will
remain after resetting controller.


WINTERIZING YOUR SYSTEM

In regions where the frost level falls below the depth of the
installed piping, it is common for systems to be “winterized”.
Several methods can be used to drain the water from the system.
If compressed air method is used, it is recommended that a
qualified licensed contractor perform this type of winterization.

WARNING! WEAR ANSI APPROVED SAFETY EYE

PROTECTION! Extreme care must always be taken when
blowing out the system with compressed air. Compressed
air can cause serious injury, including serious eye injury
from flying debris. Always wear ANSI approved safety eye
protection and do not stand over any irrigation components
(pipes, sprinklers, and valves) during blow out. SERIOUS
PERSONAL INJURY MAY RESULT IF YOU DO NOT
PROCEED AS RECOMMENDED.

Hunter Quick Check
Clearing Controller

s Memory/Resetting Controller

Winterizing Your Irrigation System