Trouble shooting, Operation 3.5. trouble shooting – CMA Dishmachines CMA-66 User Manual

Page 23

Advertising
background image

Operation

3.5. Trouble

Shooting

PROBLEM LIKELY

CAUSE

SOLUTION

Pre-wash/power wash

motor inoperative

Bad motor or capacitor

Faulty contactor

Replace defective motor

Replace contactor

Fuse is burned out

Replace fuse

Table limit switch

Remove dish rack at switch

Defective door reed switch

Replace reed switch

Defective start reed switch

Replace reed switch

Defective auto/manual switch

Replace switch

Machine inoperative

Defective 60 Sec. Timer

Replace timer

Defective 60 Sec. Timer or settings

Replace timer or change settings

Machine runs continuously

Contactor stuck

Replace contactor

Float switch

Check movement-replace it

Defective thermostat or setting

Replace thermostat or adjust

Defective heater contactor

Replace heater contactor

Defective heater

Replace heater

Defective heater switch

Replace switch

Heater (no heat)

Wire connections

Check and correct

Broken rack

Replace rack

Racks stuck

Tray track alignment

Adjust properly

Low incoming water supply

(150°F-low temp, 180 °F- high temp)

Check hot water supply

Thermostat setting

Adjust thermostat

Vent hoods

Close vents as much as possible

Low wash tank
temperature

Defective heater

Replace heater

Plugged rinse jets

Remove and clean

Pressure regulator out of adjustment Adjust

pressure

regulator

Water sol. valve coil or diaphragm

Replace or clean

Dirty rinse jets

Remove and clean jets

Low rinse water pressure
or no rinse

Defective rinse reed switch

Replace reed switch

Dispenser or settings

Check dispenser troubleshooting guide

Chemicals

Rinse pressure

Set 20 psi.

Quick drain on pre-wash end

Plumb quick drain back into pre-wash
tank above water line

Sheet pans

Use CMA sheet pan rack

Machine loosing water

Drain valves open

Close completely

Tank water level low

Check rinse pressure, drain valve open

Clogged jets

Clean jets

Low spray arm pressure

Motors connected wrong

Connect motors to reverse impeller
direction

MODEL CMA-66 Installation & Operation Manual Rev. 1.06 01/11/05