Product Dimensions

40" to 40.79"

overall height

Electricai Requirements

This appliance must be properly installed and grounded by a qualified technician in accordance
with the National Electrical Code ANSI/NFPA No. 70 (latest edition) and local electrical code

requirements.

This appliance may be connected by means of permanent “Hard Wiring” or “Power Supply
Cord Kit”.

Power supply cord is not supplied, but is available through your local electric supply house.
Use only 3-conductor or 4-conductor UL listed range cord rated at 40 amps with 125/250V

minimum voltage range. These cords may be provided with strain relief or conduit connector.

The range must be connected to the proper electricai voltage and frequency as specified on
the rating plate.
The range can be connected directly to the fused disconnect (or circuit breaker box^ through

flexible, armoured or non-metallic sheathed, copper cable (with grounding wire). Allow two to

three feet of slack in the line so that it can be moved if servicing is ever necessary.