For the kitchen furniture installer

Safety instructions

Please note that veneers and plastic coatings
on the unit housings must be treated with heat-
resistant adhesive (100°C). Unless the plastic

coatings and adhesives are heat-resistant, the
coating may deform or come loose.

The use of solid wood wall upstands behind
the hob is allowable so long as the minimum
distances indicated in the hob diagrams are

complied with.

Surface discolourations of the wall upstand are
not due to temperature effects of the appliance.
For temperature reasons, cut out any upper
panels of base units below the hob.

Owing to the risk of fire, ensure that no flam­
mable or thermally deformable objects are

placed directly below the hob.

Do not install a drawer below build-in hobs.

An intermediate panel must be fitted, that can
only be detached with tools, at least 50 mm

beneath the hob for safety (contact protec­

tion) reasons.

There should be no cross-strips below the
worktop cutout. They should be sawn back at

least as far as the worktop cutout size.

The minimum distances of hob cutouts to the

rear are indicated in the installation diagrams
(figure 5).

During installation beside an upright kitchen
housing, a safety distance of at least 50 mm
must be ensured. The side surface of the
upright kitchen housing should be lined with
heat-resistant material.

For reasons of good working practice, the
distance laterally to upright kitchen units

should be at least 300 mm.

The distance between the hob and vapour

extractor hood must be of the extent indi­
cated in the installation instructions of the

vapour extractor hood.

Hob Cutout

Use the template supplied for your “Soft Line”
ceramic hob.

Figure 5

Hobs with a width of 77 cm should be fitted

over only two 60 cm base units (rather than

three) to avoid the loss of the third drawer

space. Please make sure that the cutout is
accurately made. You should therefore use
only a good, straight fretsaw blade or else
a routing cutter.

The cutting surfaces must be sealed.
The range of the clamping brackets extends
from 30 mm to 40 mm. With thicker worktops

recesses should be provided in the worktop
at suitable points.

The clamping brackets are fastened according
to figure 6/1,2.

Hob Instailation

1. Take the mean according to figure 8.

2. Attach fixing bracket to figure 9.

3. Cut off top half fixing brackets (figure 10)

with a knife.

4. Insert hob according to (figure 7) and place

it horizontally, level in the worktop.

5. The two clamps firmly fitted on both sides

will grip under the fixing brackets (figure 11)
and retain the hob. For removing it proceed

in reverse order.

Important

Under no circumstances should drawers be

fitted in either of the base units straddled by
the hob.