Basement, Furnace, Counterflow – Bryant 394 Gas User Manual

Page 3

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

BASEMENT
FURNACE

Model

No.

A.G.A. RATINGS BTU/HR

A

В

C

D

E

F

G

H

J*

K*

GAS CON

SIZES

Filters

Approx.

Shipping

Weight

(Lb.)

Natural Propane

Input

Bonnet

Capacitj

Input

Bonnet

Capacity

Nat. Prop.

50-394 50,000

40,000 50,000

40,000 16-1/4 40-9/16 46 14-5/8 19-3/4 2-1/2 2-9/16 4" 25-7/16 2-7/8

1/2 , 1/2

14

X

25

X

1

166

80-394 80,000

64,000 75,000

60,000 16-1/4 40-9/16 46 14-5/8 19-3/4 2-1/2 2-9/16 4" 25-7/16 2-7/8

1/2

1/2

14

X

25

X

1

192

100-394 100,000

80,000 100,000

80,000 18-1/4 40-9/16 46 16-5/8 19-3/4 2-1/2 2-3/4

5" 25-7/16 2-7/8

1/2

1/2

16

X

25

X

1

213

125-394 125,000 100,000 125,000 100,000 20-1/4 40-9/16 46 18-5/8 19-3/4 2-1/2 2-3/4

5" 25-7/16 2-7/8

1/2

1/2

20

X

25

X

1

238

137-394 137,500 110,000

Not available 20-1/4 40-9/16 46 18-5/8 19-3/4 2-1/2 2-3/4

5" 25-7/16 2-7/8

1/2

1/2

20

X

25

X

1

240

165-394 165,000 132,000 150,000 120,000 28-1/4 43-3/8

51 26-5/8 17-3/4 4-1/2 4-1/2

6" 30-5/8

4-1/16 1/2

1/2 Two 16

X

25

X

1

343 .

190-394 190,000 152,000 175,000 140,000 36-1/4 43-3/8

51 34-5/8 17-3/4 4-1/2 5-1/8

2-5" 30-5/8

4-1/16

1/2

1/2 Two 16

X

25

X

1

428

220-394 220,000 176,000 200,000 160,000 36-1/4 43-3/8

51 34-5/8 17-3/4 4-1/2 5-1/8

2-5" 30-5/8

4-1/16 1/2

i/i

Two 16

X

25

X

1

428

Ratings are certified for altitudes to 2,000 feet for all gases. Ratings for altitudes over 2,000 feet are 4% less for each 1,000 feet above sea level.
Return air compartment shipped separately, knocked down.

*Optional gas inlet right and left sides provided. J = 33-5/8 and K= 3-1/2 on 50 thru 137 sizes only.

COUNTERFLOW

FURNACE

A66383

Model

No.

A.G.A. Ratings BTU/HR

Natural Propane

A

В

С

D

Е

F

G

Н

J

Kt

*

Lt

Gas Con

Sizes

Filters

Approx.

Shipping

Weight

(Lb.)

Input

Bonnet

Capacity

Input

Bonnet

Capacity

Nat. Prop.

50-394

50,000

40,000

50,000

40,000

16-1/4

26

14-3/4

тщ

4"

12-5/8

22-5/8

1-1/2 2-7/8

25-7/16

1/2

1/2

16

X

20

X

1

166

80-394

80,000

64,000

75,000

60,000

16-1/4

26

14-3/4

2-3/4

4"

12-5/8

22-5/8

1-1/2 2-7/8

25-7/16

1/2

1/2

16

X

20

X

1

185

100-394

100,000

80,000

100,000

80,000

18-1/4

26

Н

— 16-3/4

ТЩ

5"

14-5/8

22-5/8

1-1/2

2-7/8

25-7/16

1/2

1/2

Two 10

X

20

X

1

210

125-394

125,TO

100,000

125,000

100,000

202Щ

26

75

18-3/4

гЗТ4

5"

18-518 22-5/8

тш

1-7/8

25-7/16

1/2

1/2

Two 14

X

20

X

1

235

137-394

137,500

110,000

Not available 20-1/4

26

75

18-3/4

2-3/4

5"

18-5/8

22-5/8

1-1/2 2-7/8

25-7/16

1/2

1/2

Two 14

X

20

X

1

237

165-394

165,000

132,000

150,000

120,000

28-1/4

28-13/16

80 26-1/4

4-1/2

6"

25-5/8

23-5/16

1-7/8 4-1/16 30-5/8

1/2

1/2

Two 16

X

20

X

1

325

190-394

19O,0OO 152,000

175,000

140,000

36-1/4

28-13/16

80 34-1/4

5

(2) 5" 33-5/8

23-5/16

1-7/8 4-1/16 30-5/8

1/2

1/2

Two 20

X

20

X

1

405

220-394

220,000

176,000

200,000

160,000

36-1/4

28-13/16

80 34-3/4

5

(2) 5" 33-5/8

23-5/16

1-7/8 4-1/16 30-5/8

1/2

1/2

Two 20

X

20

X

1

405

*Add 1-1/4" when installed with base on combustible fioor.
tOptional gas inlet right and left sides provided. L = 33-5/8 and K =

3-1/2 on 50 thru 137 sizes only.

-

3

-