WALL MOUNTING INSTALLATION

MASTER STATION:

(1)

When wall mounting, install

sub chassis upside down. (2) When mounting to a gang
box, use sub plate (available from Aiphone) as shown in

the figure.

NOTE: Sub chassis must be ALWAYS used for heat

radiation.

CONNECTING
WIRE

SUB PLATE

GANG BOX

SUB STATION:

Attach the mounting bracket to wall or

gang box.

TERMINALS

WRING

Layout your system in advance. Determine the location of each station and wiring to each. Two conductors are

required from a master to each sub station under control of that master. Three conudctors are required between the two
masters. Door station adaptor DB-TS should be located as near master as possible. Three conductors are required to DB-TS.

* Connect a single pair of wires (non-polarized) to TB-RC phone, and to numbered station terminals on master

station which you wish to call.

* Adjust call tone volume as desired on the panel of master.
* Do not common one side of pair at any other point than at master. Doing so will affect proper operation of your

system. Refer to the connection diagrams.

* Extend a single pair of wires from terminals: S, S on master to ICR-1, extension call speaker in places where you

wish to receive a call besides at master.

Refer to the chart below and select the proper size wire for your needs.

24 AWG

22 AWG

20 AWG

18 AWG

Master to sub

750’

1,300'

2,000'

3,000'

Master to master

400'

650'

1,000'

1,600'

DB-TS to door station

300'

500'

750'

1,200'

0.5 mm

0.65 mm

0.8 mm

1.0 mm

Master to sub

230 m

400 m

600 m

900 m

Master to master

120 m

200 m

300 m

480 m

DB-TS to door station

90 m

150 m

230 m

360 m

After installation of a master and one sub station, we recommend that the system be turned on and

tested for proper operation. The system should further be tested after the addition of each five stations.

INSTALLATION OF DOOR STATION

1. Terminal N indicates the number to which door will announce.

2. DB-TS should be mounted so as to keep wiring to the master as short as possible.

3. Mount door station to wall or gang box as desired.
4. Connect terminals 1 and 2 on DB-TS to door station. Wiring is non-polarized.

5. Connect terminals -i- and — to master station. Observe polarity.

NOTE: DB-TS can not be connected to additional selector.