NEMA PHOTOCONTROL REPLACEMENT

1. The photocontrol is mounted on top the housing. FIG. 6

2. Remove the photocontrol by twisting counterclockwise and
replace.

OPTIC DISTRIBUTION AND ORIENTATION
The Talon Medium fixture is offered with some optics that
have directional distributions. For aiming purposes, the Talon
Medium was designed with the flexibility to allow each of its optics
to be rotated to any of four positions, located at 90° increments.
To change the optic orientation, open the door and remove the
lamp. Use a screwdriver to remove the four screws as shown in
FIG. 7. Reposition the optic, insert the screws and tighten securely.

These instructions do not claim to cover all details or variations in
the equipment, procedure, or process described, nor to
provide directions for meeting every possible contingency
during installation, operation or maintenance. When additional
information is desired to satisfy a problem not covered
sufficiently for user's purpose, please contact your nearest
representative.

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency
during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest
representative.

Talon Medium

Sheet 3 of 3

7/23/08

IMI-687SW

INSTALLATION INSTRUCTIONS

IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.

WARNING: Risk of Fire/Electric Shock. If not qualified, consult an electrician.
WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing.
WARNING: Risk of Burn. Disconnect power and allow fixture to cool before changing bulb or handling fixture.
WARNING: Risk of Personal Injury. Fixture may become damaged and/or unstable if not installed properly. Tighten all fixture components

to their recommended torque values.

WARNING: Risk of Fire/Electrical Shock. Upside down installation can result in overheating or accumulation of water in fixture.

Install right side up.

NOTE: Specifications and dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADW081604