3 ) - b

3) Paging speaker line connections;

a. Heaviest possible gauge of wires should be run from PG-3

to paging speaker.

Refer to the chart below and select the proper wire gauge

to meet your requirements.

AWG size

22 AWG

20 AWG

18 AWG

Distance

160'

235'

355'

Diameter

0.65 mm

0.8 mm

1.0 mm

Distance

40 m

60 m

90 m

b. When paging speakers are installed in multiple (Up to four

8 ohm paging speakers are installable), run 2 separate

wires from PG-3’s |2i2[ and |COM| terminals to each

8 ohm paging speaker.

C ADAPTOR REQUIREMENT^

PG-3 can add the feature of paging to relatively small area, where one 8 ohm paging speaker is installed. The following

requirements MUST be met for paging adaptor and power supply.

SYSTEM

STRAIGHT PAGING

TALKBACK PAGING

POWER SUPPLY FOR PG-3

TB-F

Use PG-3 with PB-1.

Use PG-3 with PB-1 and PB-2.

Supplied by system’s single

power supply (in a system of up

to 12 phones).

TB-H

Use PG-3 with PB-1 for each

block.

Use PG-3 with PB-1 and PB-2

for each block.

Supplied by system’s single

power supply (in a system of up

to 12 phones).

TS-K

Use PG-3 with PG-U for each

block.

Use PG-3 with PG-U and PA-B

for each block.

Supplied by system’s single

power supply (in a system of up

to 12 phones).

KAH

Use PG-3 with PA-1 for each

block.

Use PG-3 with PA-2 for each

block.

Separate power supply required

for PG-3 and system itself.

LAP

Connect PG-3 directly to

LAP stations.

Not available.

Supplied by system’s single

power supply.

LAH-20

Use PG-3 with LAN-1.

Not available.

Separate power supply for PG-3

and system itself.

HM-7

Connect PG-3 directly to

HM-7 stations.

Not available.

Supplied by system’s single

power supply.

-3