WIRING DIAGRAM

33V22AWG)

165722AWG)

ROOM STATION

(l) When motion detector and audio door station is not installed, have each BLACK/WHITE and RED/BROWN wires insulated.

(D The locator LED is lit on the lE/IF door station, only when MYW-CA is working.

IF-DA

To cut off the I.ED all the time, open the case and remove either lead from the PC board.

In MY-ICD system, use PS-18C/D power supply when DP-600Z is installed.

LED lead

PC BOARDS

SPECIFICATIONS

* Power source:

Supplied by main room station.

* Dimensions:

H x W x D : 163

X

121 x52 (6-1/2" x 4-3/4" x 2”)

* Weight:

ApproK. 850g (1.87 lbs.) including mounting

accessories

* Max. distance to object:

It is suggested to locate the MYW-CA at approx.

3m/10’ distance to the viewing area,

providing spotlighting illuminatin for the night.

* Image viewing area:

At 3m/10' distance; 4.7m/16' vertically 8.4m/28'
horizontally captured by pan-and-tilting operation.

Image viewing area

* Vertical (tilting)

4.7m/16'

8.4m/28'

3m/10A

The outer angle is obtained when camera is
pan-and-tilted, while the inner angle is for fixed

camera position.

Opeationai notes;

In night time, pan-aiid-tilting operation may cause flickering on the monitor, but this is not a unit disorder.
When the system with DP-600Z motion detector is powered on, it may happen that a call will be initiated by itself.
Wait for approx. 15 seconds after powered on, as the system performance can be unstable.