Electrical connections

Voltage and

current

Important

10

# Please ensure that the voltage and current indicated on the rating

plate agree with the voltage of your electricity supply.

If your appliance has been equipped with a mains lead with a

moulded-on type plug, you must comply with the following

regulations:

The plug moulded on to the lead incorporates a fuse. For

replacement, use a 5 amp BS1362 fuse. Only ASTA approved or

certified fuses should be used. If the fuse cover/carrier is lost, a

replacement cover/carried must be obtained from an electrical

goods retailer. If the socket outlets in your home are not suitable
for the plug fitted to the appliance, then the plug must be cut off and

destroyed for safety reasons, and an appropriate plug fitted.

When wiring the plug ensure that all strands of wire aré securely

retained in each terminal. Do not forget to tighten the mains lead

clamp on the plug.

This appliance complies with the following directives:
— 89/336/EEC of 03.05.1989 (including amendments 92/31/

EEC of 28.04.1992 and 93/68/EEC of 22.07.1993),
EMC directive.

Electrical connections

230 V - using fixed power supply line with plug.
240 V - using fixed power supply line (Great Britain).

Fuse rating 13 amps

(The unit should only be connected up by an authorized electrician).

See rating plate for further information.

It is recommended that the socket for the plug is sited above the

cooker hood or above the overhead cabinet.
This has 2 advantages:

1 ) The socket is not visible.

2) The appliance can easily be unplugged when necessary.

If a fixed connection is required the cooker hood should be

connected by an electrical installer registered with a competent
electricity company. An isolating device is to be provided on the

fixed wiring side. Switches with a contact opening of more than

3mm apply as isolating devices.

These include-automatic cut-out switches, fuses and contactors

(VDE0730, s. 7, Parti).